RT Journal Article SR Electronic T1 Lung function may recover after coal mine fire smoke exposure: a longitudinal cohort study JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2024.07.29.24311157 DO 10.1101/2024.07.29.24311157 A1 Holt, Nicolette R A1 Smith, Catherine L A1 Gao, Caroline X A1 Borg, Brigitte A1 Lane, Tyler J A1 Brown, David A1 Ikin, Jillian F A1 Makar, Annie A1 McCrabb, Thomas A1 Thomas, Mikayla A1 Nilsen, Kris A1 Thompson, Bruce R A1 Abramson, Michael J YR 2024 UL http://medrxiv.org/content/early/2024/07/30/2024.07.29.24311157.abstract AB Background and objective The 2014 Hazelwood coalmine fire exposed residents in nearby Morwell to high concentrations of particulate matter <2·5 µm (PM2·5) for approximately 6 weeks. This analysis aimed to evaluate the long-term impact on respiratory health.Methods Adults from Morwell and the unexposed town of Sale completed validated respiratory questionnaires and performed spirometry, gas transfer and oscillometry 3·5-4 years (Round 1) and 7·3-7·8 years (Round 2) after the fire. Individual PM2·5 exposure levels were estimated using chemical transport models mapped onto participant-reported time-location data. Mixed-effects regression models were fitted to analyse associations between PM2·5 exposure and outcomes, controlling for key confounders.Results From 519 (346 exposed) Round 1 participants, 329 (217 exposed) participated in Round 2. Spirometry and gas transfer in Round 2 were mostly lower compared with Round 1, excepting FVC (increased) and FEV1 (minimal change). The effect of mine fire-related PM2·5 exposure changed from a negative effect in Round 1 to no effect in Round 2 for both pre-(p=0·005) and post-bronchodilator FVC (p=0·032). PM2·5 was not associated with gas transfer in either round. For post-bronchodilator reactance and area under the curve, a negative impact of PM2·5 in Round 1 showed signs of recovery in Round 2 (both p<0·001).Conclusion In this novel study evaluating long-term respiratory outcomes after medium-duration high concentration PM2·5 exposure, the attenuated associations between exposure and respiratory function may indicate some recovery in lung function. With increased frequency and severity of landscape fires observed globally, these results inform public health policies and planning.KEY MESSAGES Evidence is currently lacking on the long-term sequelae of high concentration PM2·5 exposure, from extreme wildfire events lasting weeks to months, on lung physiology and function. We found that previously observed deficits in adult lung function, measured using spirometry, gas transfer and oscillometry 3.5 years after a prolonged coal mine fire, may recover in the longer-term. With increased frequency of prolonged landscape fires observed globally, these results inform public health policies and planning.Competing Interest StatementMJA declares an unrelated consultancy with Sanofi, investigator initiated grants from Pfizer, Boehringer-Ingelheim, Sanofi and GlaxoSmithKline, a speakers fee from GSK, honorarium from The Limbic and honorary membership of the Data Safety Monitoring Board of the Woolcock Institute of Medical Research. The other authors have nothing to disclose.Funding StatementThis study was funded by the Victorian State Government Department of Health. However, this paper represents the views of the authors and not the Department.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The Monash University Human Research Ethics Committee and Alfred Health Ethics Committee gave ethical approval for this work.I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.YesThe data are not available as they contain confidential information.95%CI95% Confidence IntervalAx5area under the reactance curve at frequency 5Hz.BDBronchodilatorBMIbody mass indexCOPDchronic obstructive pulmonary diseasediffdifferenceFEFForced expiratory flowFEV1Forced expiratory volume in 1 secondFVCForced vital capacityHbhaemoglobinKcoCarbon monoxide transfer coefficientPM2·5particulate matter <2·5 µg/m³Q1first quartileQ3third quartileR1Round 1R2Round 2R5resistance at 5HzR5-19difference in resistance at 5 and 19HzSDStandard DeviationTLcoTransfer/diffusion factor of the lung for carbon monoxideVAAlveolar volumeX5reactance at frequency 5Hz