Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Stability of spectral results in cardiac dual-source photon-counting CT

View ORCID ProfileLeening P. Liu, View ORCID ProfileNadav Shapira, Pooyan Sahbaee, View ORCID ProfileGrace J. Gang, Friedrich D. Knollman, View ORCID ProfileMarcus Y. Chen, View ORCID ProfileHarold I. Litt, View ORCID ProfilePeter B. Noël
doi: https://doi.org/10.1101/2022.12.07.22283222
Leening P. Liu
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
2Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
B.S.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Leening P. Liu
  • For correspondence: leening{at}seas.upenn.edu pbnoel{at}upenn.edu
Nadav Shapira
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
Ph.D.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Nadav Shapira
Pooyan Sahbaee
3Siemens Healthineers, Malvern, PA, USA
Ph.D.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Grace J. Gang
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
Ph.D.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Grace J. Gang
Friedrich D. Knollman
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
M.D., Ph.D.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marcus Y. Chen
4National Heart, Lung, and Blood Institute, Bethesda, MD, USA
M.D.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Marcus Y. Chen
Harold I. Litt
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
M.D., Ph.D.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Harold I. Litt
Peter B. Noël
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
5Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675 München, Germany
Ph.D.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Peter B. Noël
  • For correspondence: leening{at}seas.upenn.edu pbnoel{at}upenn.edu
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Objective Evaluate stability of spectral results at different heart rates, acquisition modes, and cardiac phases in first-generation clinical dual-source photon-counting CT (PCCT).

Materials and Methods A cardiac motion simulator with a coronary stenosis mimicking a 50% eccentric calcium plaque was scanned with a first-generation dual-source PCCT at five different heart rates (0, 60, 70, 80, 100 bpm). Scans were performed at 120 kVp with the three available cardiac scan modes (high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, retrospectively ECG-gated spiral). Subsequently, virtual monoenergetic images at 50, 70, and 150 keV and iodine density maps were reconstructed at both diastole and systole to investigate the effect of the cardiac phase. Full width half max (FWHM) of the stenosis, Dice score (DSC) for the stenosed region, and eccentricity of the non-stenosed region were analyzed.

Results FWHM exhibited average differences from the static FWHM across cardiac phase and heart rates of -0.20, -0.28, and -0.15 mm at VMI 150 keV for high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, and retrospectively ECG-gated spiral scans, respectively. DSC demonstrated similarity among parameters with standard deviations of 0.08, 0.09, 0.11, and 0.08 for VMI 50, 70, and 150 keV, and iodine density maps, respectively, with larger differences present at systole and with high pitch scans. Similarly, eccentricity illustrated small differences across heart rate and acquisition mode for each spectral result.

Conclusions Consistency of spectral results at different heart rates and acquisition modes for different cardiac phase demonstrates the added benefit of spectral results from PCCT to dual-source CT to further increase confidence in quantification and advance cardiovascular diagnostics.

Competing Interest Statement

The authors of this manuscript declare relationships with the following companies: Siemens Healthineers. Harold I. Litt and Peter B. Noël have a research agreement with Siemens Healthineers. Pooyan Sahbaee is an employee of Siemens Healthineers.

Funding Statement

We acknowledge support through the National Institutes of Health (R01EB030494) and Siemens Healthineers.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Footnotes

  • Source of Support: Siemens Healthineers

Data Availability

All data produced in the study are available upon reasonable request to the authors.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted December 12, 2022.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Stability of spectral results in cardiac dual-source photon-counting CT
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Stability of spectral results in cardiac dual-source photon-counting CT
Leening P. Liu, Nadav Shapira, Pooyan Sahbaee, Grace J. Gang, Friedrich D. Knollman, Marcus Y. Chen, Harold I. Litt, Peter B. Noël
medRxiv 2022.12.07.22283222; doi: https://doi.org/10.1101/2022.12.07.22283222
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Stability of spectral results in cardiac dual-source photon-counting CT
Leening P. Liu, Nadav Shapira, Pooyan Sahbaee, Grace J. Gang, Friedrich D. Knollman, Marcus Y. Chen, Harold I. Litt, Peter B. Noël
medRxiv 2022.12.07.22283222; doi: https://doi.org/10.1101/2022.12.07.22283222

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Radiology and Imaging
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)