Abstract
Motor commands for the arms and hands generally originate in contralateral motor cortex anatomically. However, ipsilateral primary motor cortex shows activity related to arm movement despite the lack of direct connections. The extent to which the activity related to ipsilateral movement is independent from that related to contralateral movement is unclear based on conflicting conclusions in prior work. Here we present the results of bilateral arm and hand movement tasks completed by two human subjects with intracortical microelectrode arrays implanted in left primary motor cortex for a clinical brain-computer interface study. Neural activity was recorded while they attempted to perform arm and hand movements in a virtual environment. This enabled us to quantify the strength and independence of motor cortical activity related to continuous movements of each arm. We also investigated the subjects’ ability to control both arms through a brain-computer interface system. Through a number of experiments, we found that ipsilateral arm movement was represented independently of, but more weakly than, contralateral arm movement. However, the representation of grasping was correlated between the two hands. This difference between hand and arm representation was unexpected, and poses new questions about the different ways primary motor cortex controls hands and arms.
Competing Interest Statement
The authors have declared no competing interest.
Clinical Trial
NCT01364480 and NCT01894802
Funding Statement
Supported by the Defense Advanced Research Projects Agency (DARPA) and Space and Naval Warfare Systems Center Pacific (SSC Pacific) under Contract No. N66001-16-C-4051 and the Revolutionizing Prosthetics program (Contract No. N66001-10-C-4056).
Author Declarations
All relevant ethical guidelines have been followed and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
Any clinical trials involved have been registered with an ICMJE-approved registry such as ClinicalTrials.gov and the trial ID is included in the manuscript.
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant Equator, ICMJE or other checklist(s) as supplementary files, if applicable.
Not Applicable
Data Availability
The datasets generated and analysed during the current study are available from the corresponding author on reasonable request.