Continuous Aerosol Medication Therapy in an in vitro High-Flow System Using Wire Mesh Technology

Jhaymie Cappiello, Carla Bremenour, Jason Boyle, Jessica Lumbard, View ORCID ProfileKamrouz Ghadimi
doi: https://doi.org/10.1101/2020.02.10.20020719
Jhaymie Cappiello
1Duke University Hospital
2Durham, North Carolina
RRT
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Carla Bremenour
1Duke University Hospital
2Durham, North Carolina
RRT
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jason Boyle
1Duke University Hospital
2Durham, North Carolina
RRT
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jessica Lumbard
1Duke University Hospital
2Durham, North Carolina
RRT
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kamrouz Ghadimi
1Duke University Hospital
2Durham, North Carolina
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Kamrouz Ghadimi
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

BACKGROUND Jet nebulizers are commonly used to provide continuous aerosolized medication therapy (CAMT). We observed the function of our CAMT system that utilizes the Aeroneb Solo nebulizer system (Aerogen Ltd, Galway, Ireland). METHODS: An observational study was performed on 2 CAMT systems with 15 Aeroneb nebulizers for each system. CAMT was simulated for 1, 2 and 3 hours. Continuous nebulization was monitored and residual volumes were recorded at the end of each simulation. Our primary endpoint was established as intermittent nebulization observed by nebulizer filling of > 1 ml during CAMT simulation. Secondary endpoint was a residual volume of < 0.1 ml.

RESULTS Out of 30 simulations in two arms, a fluid level was observed to accumulate intermittently in three nebulizers with a residual volume of 0.7 mls in one of these three. This produced a total success rate of 90%, Arm-A 80%, Arm B-100%, for our primary endpoint. Our secondary endpoint was achieved in 29 of the 30 nebulizers for an overall 97% success rate, Arm A-93%, Arm B-100%. CONCLUSION: Our Aerogen Solo CAMT system successfully emitted the set dose with 90% accuracy.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

No funding used

Author Declarations

All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.

Yes

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

Data used is present in the submitted article

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-ND 4.0 International license.
Back to top
PreviousNext
Posted February 11, 2020.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Continuous Aerosol Medication Therapy in an in vitro High-Flow System Using Wire Mesh Technology
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Continuous Aerosol Medication Therapy in an in vitro High-Flow System Using Wire Mesh Technology
Jhaymie Cappiello, Carla Bremenour, Jason Boyle, Jessica Lumbard, Kamrouz Ghadimi
medRxiv 2020.02.10.20020719; doi: https://doi.org/10.1101/2020.02.10.20020719
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Continuous Aerosol Medication Therapy in an in vitro High-Flow System Using Wire Mesh Technology
Jhaymie Cappiello, Carla Bremenour, Jason Boyle, Jessica Lumbard, Kamrouz Ghadimi
medRxiv 2020.02.10.20020719; doi: https://doi.org/10.1101/2020.02.10.20020719

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Respiratory Medicine
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)