Analysis of Effective Dose at Computed Tomography in a Modern 64 slice Multidetector CT System in an Irish Tertiary Care Centre with Local and International Reference Standards

Tadhg-Iarla Curran, Michael Maher, Patrick McLaughlin, Fíona Coffey, Siobhan O’Neill
doi: https://doi.org/10.1101/2020.04.08.20057059
Tadhg-Iarla Curran
1The Reeks Gateway, Tralee Road, Killarney, Co Kerry, Ireland
Roles: Ross Medical Practice
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: tadhgiarla{at}gmail.com
Michael Maher
2Cork University Hospital, Wilton Road, Cork, Ireland
Roles: Professor of Radiology
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Patrick McLaughlin
2Cork University Hospital, Wilton Road, Cork, Ireland
Roles: Radiology Lecturer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Fíona Coffey
1The Reeks Gateway, Tralee Road, Killarney, Co Kerry, Ireland
Roles: Ross Medical Practice
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Siobhan O’Neill
2Cork University Hospital, Wilton Road, Cork, Ireland
Roles: Radiology Lecturer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

Abstract

Background Computed tomography (CT), by its nature, imparts a high dose of ionising radiation to patients being imaged. Diagnostic Reference Levels (DRLs) are used extensively in research but are also used in practice to establish if local imaging protocols have been optimised.

Aim To audit effective dose (ED) at CT for four commonly performed examinations performed with a modern multidectector 64 slice CT (MDCT) system at large tertiary care centre by comparison with current international reference standards

Methods 800 consecutive studies of CT brain, cervical spine, thorax and abdomen-pelvis were examined. All patients were imaged on 64-slice MDCT with study-specific protocols. Dose descriptors were extracted from image dose reports. ED was calculated using dose-length product conversion coefficients for all patients. Data was collated with Irish national and local DRLs, and published international point values.

Results ED range at CT abdomen-pelvis of 2.03-26.04 mSv (mean 8.041 mSv) was 28.5% above the national DRL (9 mSv) and 26% above the local DRL (9.75 mSv). ED at CT thorax of 2.46-10.09 mSv (5.061 mSv) was 3.5% greater than local DRL (8.4mSv) and 42.5% greater than the national DRL (5.46 mSv). ED at CT brain of 2.25-8.08 mSv (3.075 mSv) was 100% above both the local (1.98 mSv) and national (2.06 mSv) DRLs. CT cervical spine ED of 1.49-21.94 mSv (5.14 mSv) was 79% greater than the local (3.07 mSv) and 100% greater than the national DRL (1.42 mSv).

Conclusions All studies exceed national DRLs. A significant optimisation potential is noted, in particular, for studies involving the head and cervical spine. A further review of study protocols is necessary to facilitate optimisation of total study radiation dose.

Competing Interest Statement

The authors have declared no competing interest.

Clinical Trial

Student Audit Project was not registered for trial ID

Funding Statement

No external funding.

Author Declarations

All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.

Yes

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

Dataset for the study is available on request.

  • Terminology & Abbreviations

    ATCM
    Automated tube current modulation
    ASIR
    Adaptive statistical iterative reconstruction
    CT
    Computed tomography
    CTDIvol
    Computed tomography dose index (volume)
    CUH
    Cork University Hospital
    DAP
    Dose-area product
    DLP
    Dose-length product
    DRL
    Diagnostic Reference Level
    ED
    Effective dose
    FBP
    Filtered back projection
    GE
    General Electrical
    HSE
    Health Service Executive
    IRCP
    International Commission on Radiological Protection
    MDCT
    Multidetector Computed Tomography
    mGy
    milliGrays
    MSCT
    Multislice Computed Tomography
    mSv
    milliSieverts
    NRF
    Noise Reduction Filtration
    PACS
    Picture archiving and communication system
    SSCT
    Single slice computed tomography
    TSL
    Total scan length
    US
    United States
  • Copyright 
    The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
    Back to top
    PreviousNext
    Posted April 15, 2020.
    Download PDF

    Supplementary Material

    Data/Code
    Email

    Thank you for your interest in spreading the word about medRxiv.

    NOTE: Your email address is requested solely to identify you as the sender of this article.

    Enter multiple addresses on separate lines or separate them with commas.
    Analysis of Effective Dose at Computed Tomography in a Modern 64 slice Multidetector CT System in an Irish Tertiary Care Centre with Local and International Reference Standards
    (Your Name) has forwarded a page to you from medRxiv
    (Your Name) thought you would like to see this page from the medRxiv website.
    CAPTCHA
    This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
    Share
    Analysis of Effective Dose at Computed Tomography in a Modern 64 slice Multidetector CT System in an Irish Tertiary Care Centre with Local and International Reference Standards
    Tadhg-Iarla Curran, Michael Maher, Patrick McLaughlin, Fíona Coffey, Siobhan O’Neill
    medRxiv 2020.04.08.20057059; doi: https://doi.org/10.1101/2020.04.08.20057059
    Twitter logo Facebook logo LinkedIn logo Mendeley logo
    Citation Tools
    Analysis of Effective Dose at Computed Tomography in a Modern 64 slice Multidetector CT System in an Irish Tertiary Care Centre with Local and International Reference Standards
    Tadhg-Iarla Curran, Michael Maher, Patrick McLaughlin, Fíona Coffey, Siobhan O’Neill
    medRxiv 2020.04.08.20057059; doi: https://doi.org/10.1101/2020.04.08.20057059

    Citation Manager Formats

    • BibTeX
    • Bookends
    • EasyBib
    • EndNote (tagged)
    • EndNote 8 (xml)
    • Medlars
    • Mendeley
    • Papers
    • RefWorks Tagged
    • Ref Manager
    • RIS
    • Zotero
    • Tweet Widget
    • Facebook Like
    • Google Plus One

    Subject Area

    • Radiology and Imaging
    Subject Areas
    All Articles
    • Addiction Medicine (349)
    • Allergy and Immunology (668)
    • Allergy and Immunology (668)
    • Anesthesia (181)
    • Cardiovascular Medicine (2648)
    • Dentistry and Oral Medicine (316)
    • Dermatology (223)
    • Emergency Medicine (399)
    • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
    • Epidemiology (12228)
    • Forensic Medicine (10)
    • Gastroenterology (759)
    • Genetic and Genomic Medicine (4103)
    • Geriatric Medicine (387)
    • Health Economics (680)
    • Health Informatics (2657)
    • Health Policy (1005)
    • Health Systems and Quality Improvement (985)
    • Hematology (363)
    • HIV/AIDS (851)
    • Infectious Diseases (except HIV/AIDS) (13695)
    • Intensive Care and Critical Care Medicine (797)
    • Medical Education (399)
    • Medical Ethics (109)
    • Nephrology (436)
    • Neurology (3882)
    • Nursing (209)
    • Nutrition (577)
    • Obstetrics and Gynecology (739)
    • Occupational and Environmental Health (695)
    • Oncology (2030)
    • Ophthalmology (585)
    • Orthopedics (240)
    • Otolaryngology (306)
    • Pain Medicine (250)
    • Palliative Medicine (75)
    • Pathology (473)
    • Pediatrics (1115)
    • Pharmacology and Therapeutics (466)
    • Primary Care Research (452)
    • Psychiatry and Clinical Psychology (3432)
    • Public and Global Health (6527)
    • Radiology and Imaging (1403)
    • Rehabilitation Medicine and Physical Therapy (814)
    • Respiratory Medicine (871)
    • Rheumatology (409)
    • Sexual and Reproductive Health (410)
    • Sports Medicine (342)
    • Surgery (448)
    • Toxicology (53)
    • Transplantation (185)
    • Urology (165)