Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Automated Contouring and Planning for Hippocampal-Avoidant Whole-Brain Radiotherapy

View ORCID ProfileChristine H. Feng, Mariel Cornell, Kevin L. Moore, View ORCID ProfileRoshan Karunamuni, View ORCID ProfileTyler M. Seibert
doi: https://doi.org/10.1101/2020.04.20.20072827
Christine H. Feng
1UC San Diego Department of Radiation Medicine and Applied Sciences, La Jolla, CA, USA
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Christine H. Feng
Mariel Cornell
1UC San Diego Department of Radiation Medicine and Applied Sciences, La Jolla, CA, USA
CMD, BS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kevin L. Moore
1UC San Diego Department of Radiation Medicine and Applied Sciences, La Jolla, CA, USA
PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Roshan Karunamuni
1UC San Diego Department of Radiation Medicine and Applied Sciences, La Jolla, CA, USA
PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Roshan Karunamuni
Tyler M. Seibert
1UC San Diego Department of Radiation Medicine and Applied Sciences, La Jolla, CA, USA
2UC San Diego Department of Bioengineering, La Jolla, CA, USA
MD, PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Tyler M. Seibert
  • For correspondence: tseibert{at}health.ucsd.edu
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Purpose Design and evaluate a workflow using commercially available artificial intelligence tools for automated hippocampal segmentation and treatment planning to efficiently generate clinically acceptable hippocampal-avoidant whole brain (HA-WBRT) radiotherapy plans.

Methods and Materials We retrospectively identified 100 consecutive adult patients treated for brain metastases outside the hippocampal region. Each patient’s T1 post-contrast brain MRI was processed using FDA-approved software that provides segmentations of brain structures in 5-7 minutes. Automated hippocampal segmentations were reviewed for accuracy and edited manually if necessary, then converted to files compatible with a commercial treatment planning system, where hippocampal avoidance regions and planning target volumes (PTV) were generated. Other organs-at-risk (OARs) were previously contoured per clinical routine. A RapidPlan knowledge-based planning routine was applied for a prescription of 30 Gy in 10 fractions using volumetric modulated arc therapy (VMAT) delivery. Plans were evaluated based on NRG CC001 dose-volume objectives.

Results Of the 100 cases, 99 (99%) had acceptable automated hippocampi segmentations without manual intervention. Knowledge-based planning was applied to all cases; the median processing time was 9 minutes 59 seconds (range 6:53 – 13:31). All plans met per-protocol dose-volume objectives for PTV per the NRG CC001 protocol. For comparison, only 66.0% of plans on NRG CC001 met PTV goals per protocol, with 26.3% within acceptable variation. In this study, 43 plans (43%) met OAR constraints, and the remaining 57 (57%) were within acceptable variation, compared to 42.9% and 48.6% on NRG CC001, respectively. No plans in this study had unacceptable dose to OARs, compared to 0.8% of manually generated plans from NRG CC001.

Conclusion An automated pipeline harnessing the efficiency of commercially available artificial intelligence tools can generate clinically acceptable VMAT HA-WBRT plans with minimal manual intervention. This process could improve clinical efficiency for a treatment established to improve patient outcomes over standard WBRT.

Competing Interest Statement

Dr. Moore reports personal fees from Varian Medical Systems, outside the submitted work. Dr. Seibert reports personal fees from Multimodal Imaging Services Corporation, outside the submitted work. The other authors have nothing to disclose.

Funding Statement

No external funding was received.

Author Declarations

All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.

Yes

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

The data that support the findings of this study are available from the corresponding author upon reasonable request.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted April 24, 2020.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Automated Contouring and Planning for Hippocampal-Avoidant Whole-Brain Radiotherapy
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Automated Contouring and Planning for Hippocampal-Avoidant Whole-Brain Radiotherapy
Christine H. Feng, Mariel Cornell, Kevin L. Moore, Roshan Karunamuni, Tyler M. Seibert
medRxiv 2020.04.20.20072827; doi: https://doi.org/10.1101/2020.04.20.20072827
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Automated Contouring and Planning for Hippocampal-Avoidant Whole-Brain Radiotherapy
Christine H. Feng, Mariel Cornell, Kevin L. Moore, Roshan Karunamuni, Tyler M. Seibert
medRxiv 2020.04.20.20072827; doi: https://doi.org/10.1101/2020.04.20.20072827

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Oncology
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)