Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Quantitative analysis of the iris surface smoothness by spectral domain optical coherence tomography in Fuchs uveitis

View ORCID ProfileMohammad Zarei, View ORCID ProfileElias Khalili Pour, View ORCID ProfileNazanin Ebrahimiadib, View ORCID ProfileHamid Riazi-Esfahani
doi: https://doi.org/10.1101/2020.05.06.20093302
Mohammad Zarei
1Retina Service, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran, Qazvin Square, South Kargar Street, Tehran 1336616351, Iran
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Mohammad Zarei
Elias Khalili Pour
1Retina Service, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran, Qazvin Square, South Kargar Street, Tehran 1336616351, Iran
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Elias Khalili Pour
Nazanin Ebrahimiadib
1Retina Service, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran, Qazvin Square, South Kargar Street, Tehran 1336616351, Iran
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Nazanin Ebrahimiadib
Hamid Riazi-Esfahani
1Retina Service, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran, Qazvin Square, South Kargar Street, Tehran 1336616351, Iran
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Hamid Riazi-Esfahani
  • For correspondence: Hamidriazi{at}gmail.com
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Purpose To demonstrate the value of “smoothness index” as a novel tool for quantitative analysis of iris surface findings in unilateral Fuchs’ uveitis (FU).

Methods In this observational study, both phakic eyes from patients with the diagnosis of unilateral FU were enrolled. All eyes underwent a complete ophthalmic examination and anterior segment optical coherence tomography(AS-OCT). The images were extracted and exported to the ImageJ software for calculating the “smoothness index (SI)”. The SI was defined as ratio of length of the straight line connecting the most peripheral and the most central points of anterior iris surface to actual length of this boundary.

Results Forty eyes from 20 patients with unilateral FU were enrolled. Mean age of patients was 40±10 years. Mean overall SI was 0.876± 0.030 in eyes with FU that was significantly more than fellow control eyes (0.841± 0.041). (p=0.005) The mean temporal and nasal SI were 0.878± 0.035 and 0.874± 0.033 in eyes with FU, compared to 0.843± 0.041 and 0.838± 0.047 in control fellow eyes, respectively. (p = 0.008 and p = 0.009, respectively)

Conclusion Iris “smoothness index” is a novel index to quantitatively document diffuse smoothness of iris anterior surface in eyes with FU. This index may facilitate diagnosis of subtle iris atrophic changes in these eyes, especially when heterochromia is absent.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

no funding was received

Author Declarations

All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.

Yes

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Footnotes

  • Declarations:

  • Financial Support: None

  • Conflict of interest: None of the authors have any proprietary interests or conflicts of interest related to this submission.

  • Availability of data and material: The data generated during or/and analysed during the current study are available from the corresponding author.

  • Code availability: Not applicable

  • Acknowledgements: The authors would like to thank Azar Rezaei, Maryam Kasiri and Nastaran Salimi for their kind contribution to this study.

Data Availability

The data generated during or/and analysed during the current study are available from the corresponding author

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted May 11, 2020.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Quantitative analysis of the iris surface smoothness by spectral domain optical coherence tomography in Fuchs uveitis
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Quantitative analysis of the iris surface smoothness by spectral domain optical coherence tomography in Fuchs uveitis
Mohammad Zarei, Elias Khalili Pour, Nazanin Ebrahimiadib, Hamid Riazi-Esfahani
medRxiv 2020.05.06.20093302; doi: https://doi.org/10.1101/2020.05.06.20093302
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Quantitative analysis of the iris surface smoothness by spectral domain optical coherence tomography in Fuchs uveitis
Mohammad Zarei, Elias Khalili Pour, Nazanin Ebrahimiadib, Hamid Riazi-Esfahani
medRxiv 2020.05.06.20093302; doi: https://doi.org/10.1101/2020.05.06.20093302

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Ophthalmology
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)