Abstract
Objective There is an unmet need to develop seizure detection algorithms from brain regions outside the epileptogenic cortex. The study aimed to demonstrate the feasibility of classifying seizures and interictal states from local field potentials (LFPs) recorded from the human thalamus-a subcortical region remote to the epileptogenic cortex. We tested the hypothesis that spectral and entropy-based features extracted from LFPs recorded from the anterior nucleus of the thalamus (ANT) can distinguish its state of ictal recruitment from other interictal states (including awake, sleep).
Approach Two supervised machine learning tools (random forest and the random kitchen sink) were used to evaluate the performance of spectral (discrete wavelet transform-DWT), and time-domain (multiscale entropy-MSE) features in classifying seizures from interictal states in patients undergoing stereo EEG evaluation for epilepsy surgery. Under the supervision of IRB, field potentials were recorded from the ANT in consenting adults with drug-resistant temporal lobe epilepsy. Seizures were confirmed in the ANT using line-length and visual inspection. Wilcoxon rank-sum (WRS) method was used to test the differences in spectral patterns between seizure and interictal (awake and sleep) states.
Main Results 79 seizures (10 patients) and 158 segments (approx. 4 hours) of interictal stereo EEG data were analyzed. The mean seizure detection latencies with line length in the ANT varied between seizure types (range 5-34 seconds). However, the DWT and MSE in the ANT showed significant changes for all seizure types within the first 20 seconds after seizure onset. The random forest (accuracy 93.9 % and false-positive 4.6%) and the random kitchen sink (accuracy 97.3% and false-positive 1.8%) classified seizures and interictal states.
Significance These results suggest that features extracted from the thalamic LFPs can be trained to detect seizures that can be used for monitoring seizure counts and for closed-loop seizure abortive interventions.
Competing Interest Statement
SP has served as a paid consultant for NeuroPace, Inc. but declares no targeted funding or compensation for this study. None of the authors share any competing interests.
Funding Statement
ET, GC, and SP would like to acknowledge the continuous support from the USA National Science Foundation Grant (NSF RII-2 FEC OIA-1632891). SP and GC would also like to acknowledge support from NIH (1RF1MH117155-01).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
IRB-170323005
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
Data Availability
Provided at reasonable request after final publicaiton of article.
Abbreviations
- ASD
- Anti-seizure drugs
- DWT
- Discrete Wavelet Transfer
- EI
- Epileptogenecity Index
- ES
- Electrographic Seizures
- FAS
- Focal Onset Aware Seizures
- FBTCS
- Focal to bilateral tonic-clonic seizures
- FIAS
- Focal onset seizures with impaired awareness
- LL
- Line Length
- MSE
- Multiscale Entropy
- RF
- Random Forest
- RKS
- Random Kitchen Sink
- RWE
- Relative Wavelet Energy
- SOZ
- seizure onset zone
- SEEG
- stereo-electroencephalography
- TLE
- Temporal lobe epilepsy
- UEO
- Unequivocal electrographic onset