Quantification of a Viromed Klinik Akut V 500 disinfection device to reduce the indirect risk of SARS-CoV-2 infection by aerosol particles

Christian J. Kähler, Thomas Fuchs, Rainer Hain
doi: https://doi.org/10.1101/2020.10.23.20218099
Christian J. Kähler
Universität der Bundeswehr München, Institut für Strömungsmechanik und Aerodynamik, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: christian.kaehler{at}unibw.de
Thomas Fuchs
Universität der Bundeswehr München, Institut für Strömungsmechanik und Aerodynamik, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rainer Hain
Universität der Bundeswehr München, Institut für Strömungsmechanik und Aerodynamik, Werner-Heisenberg-Weg 39, 85577 Neubiberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Indoor SARS-CoV-2 infections by droplets and aerosols are currently considered to be particularly significant. FFP2/3 respirator masks, which fit tightly and gap free, generally provide very good protection. In public transport, while shopping or in waiting rooms, they are therefore ideally suited to protect against direct and indirect infection. Unfortunately, these masks make it difficult to breathe and can be uncomfortable to wear in the long run. Therefore, these masks should be worn for a maximum of 3 × 75 minutes per day. These masks are therefore hardly suitable for schools or at work. The question therefore arises as to how people in closed rooms can be permanently protected from a SARS-CoV-2 infection. Large safety distances provide both self protection and protection of third parties, but they do not protect against indirect infection if the virus load in the room is high. Mouth and nose covers only offer protection of others against direct infection, but they do not protect the user against indirect infection. The same applies to faceshields and small protective walls. Indirect infections can be effectively prevented by free ventilation with windows or air conditioning systems that supply 100% outside air into the room, provided the air exchange rate is at minimum six times the room volume per hour. However, free ventilation by means of windows is rarely efficient enough, and in winter at the latest, it is no longer possible to open windows without wasting massive amounts of energy and endangering the health and well-being of people. The operation of air conditioning systems is also very energy-intensive during the cold season. Furthermore, most buildings do not have air conditioning systems. The question is therefore, how a largely safe protection against an indirect SARS-CoV-2 infection can be realized in closed rooms without wasting thermal energy and thus valuable resources. Technically, the problem can be solved with mobile disinfection devices or room air cleaners that separate the dangerous aerosol particles or inactivate the viruses by UV radiation or by contact with charge carriers. The potential of these devices is great and, since many German manufacturers produce these devices, they are also available. However, many of the devices offered do not provide effective protection because the volume flow is too small, the separation efficiency of the filters is too low and the performance of the UV and ionization unit is too weak. The Viromed Klinik Akut V 500 disinfection unit appears to meet the performance requirements and therefore the device is analyzed and evaluated in this study for its suitability to protect against SARS-CoV-2 infection.

Competing Interest Statement

The investigations were financially supported by the company Viromed GmbH, Rellingen, Germany. The Viromed Klinik Akut V 500 disinfection equipment was provided by Viromed GmbH for the investigations. The investigations were carried out in accordance with good scientific practice. The support by the company Viromed GmbH has no effect on the results presented. Prof. Kähler has received allowances as part of his salary as professor.

Funding Statement

The investigations were financially supported by the company Viromed GmbH, Rellingen, Germany. The Viromed Klinik Akut V 500 disinfection equipment was provided by Viromed GmbH for the investigations. The investigations were carried out in accordance with good scientific practice. The support by the company Viromed GmbH has no effect on the results presented. Prof. Kähler has received allowances as part of his salary as professor.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

No experiments have been conducted with or on humans or living beings, so that no permits are required.

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

Data is stored on a server of the institute and may be available on request.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted October 27, 2020.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Quantification of a Viromed Klinik Akut V 500 disinfection device to reduce the indirect risk of SARS-CoV-2 infection by aerosol particles
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Quantification of a Viromed Klinik Akut V 500 disinfection device to reduce the indirect risk of SARS-CoV-2 infection by aerosol particles
Christian J. Kähler, Thomas Fuchs, Rainer Hain
medRxiv 2020.10.23.20218099; doi: https://doi.org/10.1101/2020.10.23.20218099
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Quantification of a Viromed Klinik Akut V 500 disinfection device to reduce the indirect risk of SARS-CoV-2 infection by aerosol particles
Christian J. Kähler, Thomas Fuchs, Rainer Hain
medRxiv 2020.10.23.20218099; doi: https://doi.org/10.1101/2020.10.23.20218099

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Infectious Diseases (except HIV/AIDS)
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)