Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Performance evaluation of the Simtomax® CoronaCheck rapid diagnostic test

View ORCID ProfileP. J. Ducrest, A. Freymond, View ORCID ProfileJ.-M. Segura
doi: https://doi.org/10.1101/2020.10.28.20219667
P. J. Ducrest
1GaDia SA, Route de l’ile au bois 1A, 1870 Monthey, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for P. J. Ducrest
  • For correspondence: percevent.ducrest{at}gadia.net jmanuel.segura{at}hevs.ch
A. Freymond
2Institute of Life Technologies - School of Engineering; HES-SO // University of Applied Sciences Western Switzerland; Sion; Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J.-M. Segura
2Institute of Life Technologies - School of Engineering; HES-SO // University of Applied Sciences Western Switzerland; Sion; Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for J.-M. Segura
  • For correspondence: percevent.ducrest{at}gadia.net jmanuel.segura{at}hevs.ch
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

Abstract

The aim of this study was to evaluate the diagnostic performance of Simtomax® CoronaCheck, a serology rapid diagnostic test (RDT) for the detection of IgG and IgM against SARS-CoV-2. 48 plasma samples positive for SARS-CoV-2 based on RT-PCR and 98 negative control samples were studied. Diagnostic performance of the IgG/IgM RDT was assessed against RT-PCR and the electro-chemiluminescence immunoassay (ECLIA) Elecsys® Anti-SARS-CoV-2 total Ig. Overall, the RDT sensitivity was 92% (95% confidence interval [95%CI]: 79-97), specificity 97% (95% CI: 91-99%), PPV 94% (95% CI: 81-98) and the NPV 96% (95% CI: 89-99). When considering only samples collected ≥ 15 days post-symptoms (DPS), the sensitivity increased to 98% (95%CI: 86-100) and the specificity was 97% (95% CI: 91-99%). Two samples with 180 DPS were still positive for IgG. Globally, this IgG/IgM RDT displayed a high diagnostic accuracy for SARS-CoV-2 IgG/IgM detection in plasma samples in high COVID-19 prevalence settings. It could be effectively used, in absence of facilities for routine diagnostic serology, for samples with a DPS between 15 and 180 days.

Highlights

  • – The rapid diagnostic test Simtomax CoronaCheck displays a high sensitivity of 98% and a high specificity of 97% for SARS-CoV-2 IgG/IgM detection in plasma samples after 15 days post-symptoms.

  • – The rapid diagnostic test Simtomax CoronaCheck can detect SARS-CoV-2 antibodies in plasma up to 180 days after symptom onset.

  • – The rapid diagnostic test Simtomax CoronaCheck could be effectively used as an alternative to serological analysis using laboratory facilities.

Competing Interest Statement

Percevent J Ducrest has a R&D mandate with Augurix SA, the manufacturer of the RDT used in this study. Augurix SA had no role in the study design, the realization nor in result interpretation. The other authors have no conflict of interest to disclose.

Funding Statement

This research was financially supported by the HES-SO Valais-Wallis.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

This study was evaluated by the Ethics Committee of Canton de Vaud, Lausanne, Switzerland (CER-VD) and they judged that it did not deserve a specific approval being only a quality assessment of diagnostic tests with foreign residual samples.

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

Data are available in Supplementary Material

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-ND 4.0 International license.
Back to top
PreviousNext
Posted November 01, 2020.
Download PDF

Supplementary Material

Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Performance evaluation of the Simtomax® CoronaCheck rapid diagnostic test
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Performance evaluation of the Simtomax® CoronaCheck rapid diagnostic test
P. J. Ducrest, A. Freymond, J.-M. Segura
medRxiv 2020.10.28.20219667; doi: https://doi.org/10.1101/2020.10.28.20219667
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Performance evaluation of the Simtomax® CoronaCheck rapid diagnostic test
P. J. Ducrest, A. Freymond, J.-M. Segura
medRxiv 2020.10.28.20219667; doi: https://doi.org/10.1101/2020.10.28.20219667

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Infectious Diseases (except HIV/AIDS)
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)