Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Interaural place-of-stimulation mismatch estimates using CT scans and binaural perception, but not pitch, are consistent in cochlear-implant users

View ORCID ProfileJoshua G. W. Bernstein, Kenneth K. Jensen, Olga A. Stakhovskaya, Jack H. Noble, Michael Hoa, H. Jeffery Kim, Robert Shih, Elizabeth Kolberg, Miranda Cleary, View ORCID ProfileMatthew J. Goupell
doi: https://doi.org/10.1101/2021.02.19.21251930
Joshua G. W. Bernstein
1National Military Audiology and Speech Pathology Center, Walter Reed, National Military Medical Center, Bethesda, Maryland, United States, 20889.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Joshua G. W. Bernstein
  • For correspondence: joshua.g.bernstein.civ{at}mail.mil
Kenneth K. Jensen
1National Military Audiology and Speech Pathology Center, Walter Reed, National Military Medical Center, Bethesda, Maryland, United States, 20889.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Olga A. Stakhovskaya
2Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, United States, 20742.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jack H. Noble
3Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, United States, 37232.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Hoa
4Department of Otolaryngology-Head and Neck Surgery, Georgetown University Medical Center, Washington, DC, United States, 20057.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H. Jeffery Kim
4Department of Otolaryngology-Head and Neck Surgery, Georgetown University Medical Center, Washington, DC, United States, 20057.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Robert Shih
5Department of Radiology, Walter Reed National Military Medical Center, Bethesda, Maryland, United States, 20889.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Elizabeth Kolberg
2Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, United States, 20742.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Miranda Cleary
2Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, United States, 20742.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Matthew J. Goupell
2Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, United States, 20742.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Matthew J. Goupell
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

ABSTRACT

Bilateral cochlear implants (BI-CIs) or a CI for single-sided deafness (SSD; one normally functioning acoustic ear) can partially restore spatial-hearing abilities including sound localization and speech understanding when there are competing sounds. However for these populations, frequency information is not explicitly aligned across the ears, resulting in interaural place-of-stimulation mismatch. This diminishes spatial-hearing abilities because binaural encoding occurs in interaurally frequency-matched neurons. This study examined whether plasticity – the reorganization of central neural pathways over time – can compensate for peripheral interaural place mismatch. We hypothesized differential plasticity across two systems: none for binaural processing but adaptation toward the frequencies delivered by the specific electrodes for sequential pitch perception. Interaural place mismatch was evaluated in 43 human subjects (20 BI-CI and 23 SSD-CI, both sexes) using interaural-time-difference (ITD) discrimination (simultaneous bilateral stimulation), place-pitch ranking (sequential bilateral stimulation), and physical electrode- location estimates from computed-tomography (CT) scans. On average, CT scans revealed relatively little BI-CI interaural place mismatch (26° insertion-angle mismatch), but relatively large SSD-CI mismatch, particularly at the apical end of the array (166° for an electrode tuned to 300 Hz, decreasing to 14° at 7000 Hz). ITD and CT measurements were in agreement, suggesting little binaural-system plasticity to mismatch. The pitch measurements did not agree with the binaural and CT measurements, suggesting plasticity for pitch encoding or procedural biases. The combined results show that binaural processing may be optimized by using CT-scan information, but not pitch measurements, to program the CI frequency allocation to reduce interaural place mismatch.

SIGNIFICANCE STATEMENT Placement of electrode arrays in users of cochlear implants (CIs; bionic auditory prostheses that partially restore hearing) does not align the frequency information to acoustic neural encoding across the ears. This interaural place-of-stimulation mismatch diminishes spatial hearing abilities. This study shows that for experienced adult CI users with two CIs or with one CI and one normal-hearing ear, the best possible binaural sensitivity occurs when the same cochlear location is stimulated in both ears. This means that binaural brainstem pathways do not experience “plasticity” to compensate for interaural place mismatch – i.e., they do not reorganize to respond to input from different cochlear places. Therefore, explicit correction of interaural place mismatch by a clinician is necessary to derive maximum spatial-hearing benefits.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

Research reported in this article was supported by the National Institute On Deafness And Other Communication Disorders of the National Institutes of Health under Award Numbers R01 DC015798 (J.G.W.B. and M.J.G.) and R01 DC014037 (J.H.N.).

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Research was approved by the IRBs for Walter Reed National Military Medical Center and University of Maryland - College Park

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

The raw data were generated at Walter Reed National Military Center and the University of Maryland - College Park. The authors confirm that the derived data supporting the findings of this study are available within the article.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted February 27, 2021.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Interaural place-of-stimulation mismatch estimates using CT scans and binaural perception, but not pitch, are consistent in cochlear-implant users
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Interaural place-of-stimulation mismatch estimates using CT scans and binaural perception, but not pitch, are consistent in cochlear-implant users
Joshua G. W. Bernstein, Kenneth K. Jensen, Olga A. Stakhovskaya, Jack H. Noble, Michael Hoa, H. Jeffery Kim, Robert Shih, Elizabeth Kolberg, Miranda Cleary, Matthew J. Goupell
medRxiv 2021.02.19.21251930; doi: https://doi.org/10.1101/2021.02.19.21251930
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Interaural place-of-stimulation mismatch estimates using CT scans and binaural perception, but not pitch, are consistent in cochlear-implant users
Joshua G. W. Bernstein, Kenneth K. Jensen, Olga A. Stakhovskaya, Jack H. Noble, Michael Hoa, H. Jeffery Kim, Robert Shih, Elizabeth Kolberg, Miranda Cleary, Matthew J. Goupell
medRxiv 2021.02.19.21251930; doi: https://doi.org/10.1101/2021.02.19.21251930

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Otolaryngology
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)