Computed-tomography estimates of interaural mismatch in insertion depth and scalar location in bilateral cochlear-implant users

View ORCID ProfileMatthew J. Goupell, Jack H. Noble, Sandeep A. Phatak, Elizabeth Kolberg, Miranda Cleary, Olga A. Stakhovskaya, Kenneth K. Jensen, Michael Hoa, H. Jeffrey Kim, View ORCID ProfileJoshua G. W. Bernstein
doi: https://doi.org/10.1101/2021.02.26.21252533
Matthew J. Goupell
1Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Matthew J. Goupell
  • For correspondence: goupell{at}umd.edu
Jack H. Noble
2Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN, United States
3Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, TN, United States
4Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sandeep A. Phatak
5National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, MD, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Elizabeth Kolberg
1Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Miranda Cleary
1Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Olga A. Stakhovskaya
1Department of Hearing and Speech Sciences, University of Maryland, College Park, MD, United States
5National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, MD, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kenneth K. Jensen
5National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, MD, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Hoa
6Department of Otolaryngology-Head and Neck Surgery, Georgetown University Medical Center, Washington, DC, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
H. Jeffrey Kim
6Department of Otolaryngology-Head and Neck Surgery, Georgetown University Medical Center, Washington, DC, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Joshua G. W. Bernstein
5National Military Audiology and Speech Pathology Center, Walter Reed National Military Medical Center, Bethesda, MD, United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Joshua G. W. Bernstein
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

ABSTRACT

Hypothesis We hypothesized that the bilateral cochlear-implant (BI-CI) users would have a range of interaural insertion-depth mismatch because of different physical placements or characteristics of the arrays, but less than half of electrodes would have less than 75° or 3 mm of interaural insertion-depth mismatch. We also hypothesized that interaural insertion- depth mismatch would be more prevalent nearer the apex, when electrodes were located outside of scala tympani (i.e., possible interaural scalar mismatch), and when the arrays were a mix of pre-curved and straight types.

Background Brainstem neurons in the superior olivary complex are exquisitely sensitive to interaural differences, the cues to sound localization. These binaurally sensitive neurons rely on interaurally place-of-stimulation-matched inputs at the periphery. BI-CI users may have interaural differences in insertion depth and scalar location, causing interaural place- of-stimulation mismatch that impairs binaural abilities.

Methods Insertion depths and scalar locations were calculated from temporal-bone computed-tomography (CT) scans of 107 BI-CI users (27 Advanced Bionics, 62 Cochlear, and 18 Med-El). Each subject had either both pre-curved, both straight, or one of each type of array (mixed).

Results The median interaural insertion-depth mismatch was 23.4° or 1.3 mm. Relatively large interaural insertion-depth mismatch sufficient to disrupt binaural processing occurred for about 15% of electrode pairs [defined as >75° (13.0% of electrode pairs) or >3 mm (19.0% of electrode pairs)]. There was a significant three-way interaction of insertion depth, scalar location, and array type. Interaural insertion-depth mismatch was most prevalent when electrode pairs were more apically located, electrode pairs had interaural scalar mismatch (i.e., one in Scala Tympani, one in Scala Vestibuli), and when the arrays were both pre-curved.

Conclusion Large interaural insertion-depth mismatch can occur in BI-CI users. For new BI-CI users, improved surgical techniques to avoid interaural insertion-depth and scalar mismatch is recommended. For existing BI-CI users with interaural insertion-depth mismatch, interaural alignment of clinical frequency allocation tables by an audiologist might remediate any negative consequences to spatial-hearing abilities.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

Research reported in this publication was supported by the National Institute On Deafness And Other Communication Disorders of the National Institutes of Health under Award Number R01DC015798 (M.J.G. and J.G.B.W.), R01DC014037 (J.N.), and R01DC014462 (Dawant).

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Rearch was approved by Institutional Review Boards at University of Maryland - College Park and Vanderbilt University.

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

The authors confirm that the data supporting the findings of this study are available within the article.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted March 01, 2021.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Computed-tomography estimates of interaural mismatch in insertion depth and scalar location in bilateral cochlear-implant users
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Computed-tomography estimates of interaural mismatch in insertion depth and scalar location in bilateral cochlear-implant users
Matthew J. Goupell, Jack H. Noble, Sandeep A. Phatak, Elizabeth Kolberg, Miranda Cleary, Olga A. Stakhovskaya, Kenneth K. Jensen, Michael Hoa, H. Jeffrey Kim, Joshua G. W. Bernstein
medRxiv 2021.02.26.21252533; doi: https://doi.org/10.1101/2021.02.26.21252533
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Computed-tomography estimates of interaural mismatch in insertion depth and scalar location in bilateral cochlear-implant users
Matthew J. Goupell, Jack H. Noble, Sandeep A. Phatak, Elizabeth Kolberg, Miranda Cleary, Olga A. Stakhovskaya, Kenneth K. Jensen, Michael Hoa, H. Jeffrey Kim, Joshua G. W. Bernstein
medRxiv 2021.02.26.21252533; doi: https://doi.org/10.1101/2021.02.26.21252533

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Otolaryngology
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)