ABSTRACT
Pituitary microadenoma (PM) is often difficult to detect by MR imaging alone. We employed a computer-aided PM diagnosis (PM-CAD) system based on deep learning to assist radiologists in clinical workflow. We enrolled 1,228 participants and stratified into 3 non-overlapping cohorts for training, validation and testing purposes. Our PM-CAD system outperformed 6 existing established convolutional neural network models for detection of PM. In test dataset, diagnostic accuracy of PM-CAD system was comparable to radiologists with > 10 years of professional expertise (94% versus 95%). The diagnostic accuracy in internal and external dataset was 94% and 90%, respectively. Importantly, PM-CAD system detected the presence of PM that had been previously misdiagnosed by radiologists. This is the first report showing that PM-CAD system is a viable tool for detecting PM. Our results suggest that PM-CAD system is applicable to radiology departments, especially in primary health care institutions.
Competing Interest Statement
The authors have declared no competing interest.
Clinical Protocols
http://www.chictr.org.cn/index.aspx
Funding Statement
This study was funded by National Key R&D Program of China (2017YFA0105803), the General Program of National Natural Science Foundation of China (U20A20185, 81770826, 61972435), the Key Area R&D Program of Guangdong Province (2019B020227003), the Natural Science Foundation of Guangdong Province (2019A1515011271), the Science and Technology Plan Projects of Guangzhou (202007040003), and the Science and Technology Innovation Committee of Shenzhen Municipality (JCYJ20190807152209394).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This study is approved by the research ethics committee of the Institute of Basic Research in Clinical Medicine, The Third Affiliated Hospital of Sun Yat-Sen University ([2020]02-089-01). This research is registered at the Chinese Clinical Trials Registry (http://www.chictr.org.cn/index.aspx) with the number ChiCTR2000032762.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
We declare there is no conflict of interest.
Data Availability
All data have been presented in the manuscript and supplemental information.