Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Performance Comparison of a Flow Cytometry-based and Two Commercial Chemiluminescent Immunoassays for Detection and Quantification of Antibodies Binding to SARS-CoV-2 Spike Protein

Arantxa Valdivia, Fabián Tarín, María Jesús Alcaraz, Paula Piñero, Ignacio Torres, Francisco Marco, Eliseo Albert, David Navarro
doi: https://doi.org/10.1101/2021.04.06.21254995
Arantxa Valdivia
1Microbiology Service, Clinic University Hospital, INCLIVA Health Research Institute, Valencia, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Fabián Tarín
2Hematology Department, Hospital General Universitario Alicante, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
María Jesús Alcaraz
1Microbiology Service, Clinic University Hospital, INCLIVA Health Research Institute, Valencia, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Paula Piñero
2Hematology Department, Hospital General Universitario Alicante, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ignacio Torres
1Microbiology Service, Clinic University Hospital, INCLIVA Health Research Institute, Valencia, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Francisco Marco
3Immunology Department, Hospital General Universitario Alicante, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Eliseo Albert
1Microbiology Service, Clinic University Hospital, INCLIVA Health Research Institute, Valencia, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
David Navarro
1Microbiology Service, Clinic University Hospital, INCLIVA Health Research Institute, Valencia, Spain
4Department of Microbiology, School of Medicine, University of Valencia, Valencia, Spain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: david.navarro{at}uv.es
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

ABSTRACT

The performance of a laboratory-developed quantitative IgG/IgA flow cytometry-based immunoassay (FCI) using Jurkat T cells stably expressing full-length native S protein was compared against Elecsys® electrochemiluminiscent (ECLIA) Anti-SARS-CoV-2 S (Roche Diagnostics, Pleasanton, CA, USA), and LIAISON® SARS-CoV-2 TrimericS IgG chemiluminiscent assay (CLIA) (Diasorin S.p.a, Saluggia, IT) for detection and quantitation of SARS-CoV-2-specific antibodies. A total of 225 serum/plasma specimens from 120 acute or convalescent COVID-19 individuals were included. Overall, IgG/IgA-FCI yielded the highest number of positives (n=179), followed by IgA-FCI (n=177), Roche ECLIA (n=175), IgG-FCI (n=172) and Diasorin CLIA (n=154). Positive percent agreement between FCI and compared immunoassays was highest for Roche ECLIA, ranging from 96.1% (IgG/IgA-FCI) to 97.7% (IgG-FCI), whereas negative percent agreement was higher between FCI and Diasosin CLIA, regardless of antibody isotype. A strong correlation (Rho:0.6-0.8) was found between IgG-FCI or IgA-FCI levels and antibodies quantified by Roche ECLIA and Diasorin CLIA. The trajectory of antibody levels delineated by the different immunoassays in 22 of patients with sequential specimens (≥3) was frequently discordant, with the exception of IgG and IgA determined by FCI assay and to a lesser extent antibodies quantified by Roche ECLIA and Diasorin CLIA. The data suggest that FCI may outperform Roche ECLIA and Diasorin CLIA in terms of clinical sensitivity for serological diagnosis of SARS-CoV-2 infection.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

No external funding was received.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

The study was approved by the Ethical Committee of Hospital Cl&iacutenico Universitario INCLIVA.

All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

The data that support the findings of this study are available on request from the corresponding author.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted April 09, 2021.
Download PDF

Supplementary Material

Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Performance Comparison of a Flow Cytometry-based and Two Commercial Chemiluminescent Immunoassays for Detection and Quantification of Antibodies Binding to SARS-CoV-2 Spike Protein
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Performance Comparison of a Flow Cytometry-based and Two Commercial Chemiluminescent Immunoassays for Detection and Quantification of Antibodies Binding to SARS-CoV-2 Spike Protein
Arantxa Valdivia, Fabián Tarín, María Jesús Alcaraz, Paula Piñero, Ignacio Torres, Francisco Marco, Eliseo Albert, David Navarro
medRxiv 2021.04.06.21254995; doi: https://doi.org/10.1101/2021.04.06.21254995
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Performance Comparison of a Flow Cytometry-based and Two Commercial Chemiluminescent Immunoassays for Detection and Quantification of Antibodies Binding to SARS-CoV-2 Spike Protein
Arantxa Valdivia, Fabián Tarín, María Jesús Alcaraz, Paula Piñero, Ignacio Torres, Francisco Marco, Eliseo Albert, David Navarro
medRxiv 2021.04.06.21254995; doi: https://doi.org/10.1101/2021.04.06.21254995

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Infectious Diseases (except HIV/AIDS)
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)