Perceived Timing of Cutaneous Vibration and Intracortical Microstimulation of Human Somatosensory Cortex

View ORCID ProfileBreanne Christie, View ORCID ProfileLuke E. Osborn, View ORCID ProfileDavid P. McMullen, View ORCID ProfileAmbarish S. Pawar, View ORCID ProfileTessy M. Thomas, View ORCID ProfileSliman J. Bensmaia, Pablo A. Celnik, View ORCID ProfileMatthew S. Fifer, View ORCID ProfileFrancesco V. Tenore
doi: https://doi.org/10.1101/2021.12.28.21268447
Breanne Christie
1Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Breanne Christie
  • For correspondence: breanne.christie.phd{at}gmail.com
Luke E. Osborn
1Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Luke E. Osborn
David P. McMullen
2National Institute of Mental Health, National Institutes of Health, Bethesda, MD, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for David P. McMullen
Ambarish S. Pawar
3Department of Physical Medicine and Rehabilitation, Johns Hopkins University, Baltimore, MD, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Ambarish S. Pawar
Tessy M. Thomas
4Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Tessy M. Thomas
Sliman J. Bensmaia
5Department of Organismal Biology and Anatomy, University of Chicago, Illinois, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Sliman J. Bensmaia
Pablo A. Celnik
3Department of Physical Medicine and Rehabilitation, Johns Hopkins University, Baltimore, MD, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Matthew S. Fifer
1Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Matthew S. Fifer
Francesco V. Tenore
1Research and Exploratory Development Department, Johns Hopkins University Applied Physics Laboratory, Laurel, MD, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Francesco V. Tenore
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Background Electrically stimulating the somatosensory cortex can partially restore the sense of touch. Though this technique bypasses much of the neuroaxis, prior studies with non-human primates have found that conscious detection of touch elicited by intracortical microstimulation (ICMS) lags behind the detection of vibration applied to the skin. These findings may have been influenced by a mismatch in stimulus intensity; typically, vibration is perceived as more intense than ICMS, which can significantly impact temporal perception.

Objective The goal of this study was to evaluate the relative latency at which intensity-matched vibration and ICMS are perceived in a human subject.

Methods A human participant implanted with microelectrode arrays in somatosensory cortex performed a reaction time task and a temporal order judgment (TOJ) task. In the reaction time task, the participant was presented with vibration or ICMS and verbal response times were obtained. In the TOJ task, the participant was sequentially presented with a pair of stimuli – vibration followed by ICMS or vice versa – and reported which stimulus occurred first.

Results When vibration and ICMS were matched in intensity at a “high” stimulus level, the reaction time to vibration was 48 ms faster than ICMS. When both stimuli were perceived as lower in intensity, the difference in reaction time was even larger: vibration was perceived 90 ms before ICMS. However, in the TOJ task, vibratory and ICMS sensations arose at comparable latencies, with points of subjective simultaneity that were not significantly different from zero.

Conclusions Because the perception of ICMS is slower than that of intensity-matched vibration, it may be necessary to stimulate at stronger ICMS intensities (thus decreasing reaction time) when incorporating ICMS sensory feedback into neural prostheses.

Competing Interest Statement

The authors have declared no competing interest.

Clinical Trial

NCT03161067

Funding Statement

This work was made possible, in part, through financial support from Defense Advanced Research Projects Agency (DARPA) under the Neurally Enhanced Operations program (contract number HR001120C0120) and the Johns Hopkins University Applied Physics Laboratory. In addition, this work was supported with the resources and use of facilities at the Johns Hopkins Hospital.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

The study protocol was approved by the U.S. Food and Drug Administration, the Johns Hopkins Institutional Review Board (JH IRB) and the Naval Information Warfare Center Human Research Protection Office.

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Footnotes

  • This version of the manuscript has been revised to accommodate one round of peer-reviewed feedback from a journal submission.

Data Availability

All data produced in the present study are available upon reasonable request to the authors.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted March 28, 2022.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Perceived Timing of Cutaneous Vibration and Intracortical Microstimulation of Human Somatosensory Cortex
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Perceived Timing of Cutaneous Vibration and Intracortical Microstimulation of Human Somatosensory Cortex
Breanne Christie, Luke E. Osborn, David P. McMullen, Ambarish S. Pawar, Tessy M. Thomas, Sliman J. Bensmaia, Pablo A. Celnik, Matthew S. Fifer, Francesco V. Tenore
medRxiv 2021.12.28.21268447; doi: https://doi.org/10.1101/2021.12.28.21268447
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Perceived Timing of Cutaneous Vibration and Intracortical Microstimulation of Human Somatosensory Cortex
Breanne Christie, Luke E. Osborn, David P. McMullen, Ambarish S. Pawar, Tessy M. Thomas, Sliman J. Bensmaia, Pablo A. Celnik, Matthew S. Fifer, Francesco V. Tenore
medRxiv 2021.12.28.21268447; doi: https://doi.org/10.1101/2021.12.28.21268447

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Neurology
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)