Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Accurate 3D Positron Range Correction Method for Heterogeneous Material Densities in PET

Chong Li, Jürgen Scheins, Lutz Tellmann, Ahlam Issa, Long Wei, N. Jon Shah, Christoph Lerche
doi: https://doi.org/10.1101/2022.08.16.22278715
Chong Li
1Institute of Neuroscience and Medicine, INM-4, Forschungszentrum GmbH, Jülich, Germany
2Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: c.li{at}fz-juelich.de
Jürgen Scheins
1Institute of Neuroscience and Medicine, INM-4, Forschungszentrum GmbH, Jülich, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lutz Tellmann
1Institute of Neuroscience and Medicine, INM-4, Forschungszentrum GmbH, Jülich, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ahlam Issa
1Institute of Neuroscience and Medicine, INM-4, Forschungszentrum GmbH, Jülich, Germany
4Department of Neurology, RWTH Aachen University, Aachen, Germany
5JARA—BRAIN—Translational Medicine, RWTH Aachen University, Aachen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Long Wei
2Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
N. Jon Shah
1Institute of Neuroscience and Medicine, INM-4, Forschungszentrum GmbH, Jülich, Germany
3Institute of Neuroscience and Medicine, INM-11, Forschungszentrum GmbH, Jülich, Germany
4Department of Neurology, RWTH Aachen University, Aachen, Germany
5JARA—BRAIN—Translational Medicine, RWTH Aachen University, Aachen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christoph Lerche
1Institute of Neuroscience and Medicine, INM-4, Forschungszentrum GmbH, Jülich, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Objective The positron range is a fundamental, detector-independent physical limitation to special resolution in positron emission tomography (PET) as it causes a significant blurring of the reconstructed PET images. A major challenge for positron range correction methods is to provide accurate range kernels that inherently incorporate the generally inhomogeneous stopping power, especially at tissue boundaries. In this work, we propose a novel approach to generate accurate three-dimensional (3-D) blurring kernels both in homogenous and heterogeneous media to improve PET spatial resolution.

Approach In the proposed approach, positron energy deposition was approximately tracked along straight paths, depending on the positron stopping power of the underlying material. The positron stopping power was derived from the attenuation coefficient of 511keV gamma photons according to the available PET attenuation maps. Thus, the history of energy deposition is taken into account within the range of kernels. Special emphasis was placed on facilitating the very fast computation of the positron annihilation probability in each voxel.

Results Positron path distributions of 18F in low-density polyurethane were in high agreement with Geant4 simulation at an annihilation probability larger than 10−2∼10−3 of the maximum annihilation probability. The Geant4 simulation was further validated with measured 18F depth profiles in these polyurethane phantoms. The tissue boundary of water with cortical bone and lung was correctly modeled. Residual artifacts from the numerical computations were in the range of 1%. The calculated annihilation probability in voxels shows an overall difference of less than 20% compared to the Geant4 simulation.

Significance The proposed method significantly improves spatial resolution for non-standard isotopes by providing accurate range kernels, even in the case of significant tissue inhomogeneities.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

The research was supported by the Helmholtz-OCPC (Office of China Postdoc Council) Postdoc-Program through the Forschungszentrum Juelich GmbH. This work was also supported by the China National Natural Science Foundation (Grant Nos. U1932162).

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Data Availability

All data produced in the present study are available upon reasonable request to the authors

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted August 19, 2022.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Accurate 3D Positron Range Correction Method for Heterogeneous Material Densities in PET
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Accurate 3D Positron Range Correction Method for Heterogeneous Material Densities in PET
Chong Li, Jürgen Scheins, Lutz Tellmann, Ahlam Issa, Long Wei, N. Jon Shah, Christoph Lerche
medRxiv 2022.08.16.22278715; doi: https://doi.org/10.1101/2022.08.16.22278715
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Accurate 3D Positron Range Correction Method for Heterogeneous Material Densities in PET
Chong Li, Jürgen Scheins, Lutz Tellmann, Ahlam Issa, Long Wei, N. Jon Shah, Christoph Lerche
medRxiv 2022.08.16.22278715; doi: https://doi.org/10.1101/2022.08.16.22278715

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Radiology and Imaging
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)