Blink rate measured in situ decreases while reading from printed text or digital devices, regardless of task duration, complexity or working distance

View ORCID ProfileNgozi Charity Chidi-Egboka, View ORCID ProfileIsabelle Jalbert, Jiaying Chen, View ORCID ProfileNancy E. Briggs, View ORCID ProfileBlanka Golebiowski
doi: https://doi.org/10.1101/2022.11.19.22282503
Ngozi Charity Chidi-Egboka
1School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, NSW 2052, Australia
OD, MPH
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Ngozi Charity Chidi-Egboka
  • For correspondence: n.chidi-egboka{at}unsw.edu.au
Isabelle Jalbert
1School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, NSW 2052, Australia
OD, MPH, PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Isabelle Jalbert
Jiaying Chen
1School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, NSW 2052, Australia
BSc, MOptom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Nancy E. Briggs
1School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, NSW 2052, Australia
2Mark Wainwright Analytical Centre, UNSW Sydney
PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Nancy E. Briggs
Blanka Golebiowski
1School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, NSW 2052, Australia
BOptom, PhD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Blanka Golebiowski
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

Abstract

Purpose To compare blinking measured in situ during various tasks and examine relationships with ocular surface symptoms. Day-to-day repeatability of blink rate and interblink interval was assessed.

Methods Twenty-four students (28.6±6.3 years; 8M:16F) completed six reading tasks (printed text, laptop, TV, smartphone, smartphone at 50% brightness, smartphone with complex text), and two non-reading tasks (conversation, walking) in a randomised cross-over study. Ocular surface symptoms and clinical signs were assessed. Blink rate and interblink interval were measured using a wearable eye tracking headset. Blink parameters were compared across tasks and time (linear mixed model and post hoc comparisons with Bonferroni correction). Associations between blinking, symptoms, ocular surface, and clinical signs were assessed (Spearman’s correlation). The smartphone reading task was completed twice to determine coefficient of repeatability.

Results Blink rate was lower (mean 10.7±9.7 blinks/min) and interblink interval longer (mean 9.6±8.7s) during all reading tasks compared to conversation (mean 32.4±12.4 blinks/min; 1.5±0.6s) and walking (mean 31.3±15.5 blinks/min; 1.9±1.3s) (p<0.001). There were no significant differences in blink parameters between any of the reading tasks, nor between conversation and walking. Changes in blinking occurred within one minute of starting the task. No associations were evident between blink rate or interblink interval and ocular surface symptoms or signs. Coefficient of repeatability was ±12.4 blinks/min for blink rate and ±18.8s for interblink interval.

Conclusion Spontaneous blinking can be reliably measured in situ. Blink rate was reduced and interblink interval increased during reading compared to conversation and walking. Changes in blinking were immediate and sustained, and not associated with ocular surface symptoms or signs.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

This research did not receive specific funding from agencies in the public, commercial, or not-for-profit sectors. The first author, NC received a UNSW Tuition Fee Remission Postgraduate Research Scholarship and the Australian Government Research Training Program Thesis Completion Scholarship. The research was also supported by the Dorothy Carlborg Research Grant from the Cornea and Contact Lens Society of Australia, and the UNSW Faculty of Science Research Infrastructure Scheme. The funding sources have no involvement in the study design, conduct of the research, collection, analysis and interpretation of data, writing of the report, preparation of the article or in the decision to submit the article for publication.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Approval was obtained from the UNSW Sydney Human Research Ethics Advisory Panel

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Footnotes

  • Commercial relationship disclosures 1. Ngozi Charity Chidi-Egboka, None declared; 2. Isabelle Jalbert, None declared; 3. Jiaying Chen, None declared; 4. Nancy E. Briggs, None declared; 5. Blanka Golebiowski, None declared

  • Funding This research did not receive specific funding from agencies in the public, commercial, or not-for-profit sectors.

    The first author, NC received a UNSW Tuition Fee Remission Postgraduate Research Scholarship and the Australian Government Research Training Program Thesis Completion Scholarship. The research was also supported by the Dorothy Carlborg Research Grant from the Cornea and Contact Lens Society of Australia, and the UNSW Faculty of Science Research Infrastructure Scheme. The funding sources have no involvement in the study design, conduct of the research, collection, analysis and interpretation of data, writing of the report, preparation of the article or in the decision to submit the article for publication.

Data Availability

The datasets generated during and/or analysed during the current study are available in the Mendeley Data repository

https://data.mendeley.com/drafts/j63x6bxj8k

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted November 22, 2022.
Download PDF

Supplementary Material

Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Blink rate measured in situ decreases while reading from printed text or digital devices, regardless of task duration, complexity or working distance
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Blink rate measured in situ decreases while reading from printed text or digital devices, regardless of task duration, complexity or working distance
Ngozi Charity Chidi-Egboka, Isabelle Jalbert, Jiaying Chen, Nancy E. Briggs, Blanka Golebiowski
medRxiv 2022.11.19.22282503; doi: https://doi.org/10.1101/2022.11.19.22282503
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Blink rate measured in situ decreases while reading from printed text or digital devices, regardless of task duration, complexity or working distance
Ngozi Charity Chidi-Egboka, Isabelle Jalbert, Jiaying Chen, Nancy E. Briggs, Blanka Golebiowski
medRxiv 2022.11.19.22282503; doi: https://doi.org/10.1101/2022.11.19.22282503

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Ophthalmology
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)