Comparative evaluation of serum lithium estimation in serum samples using plain glass vial and serum clot activator vacutainer by reflectance photometry principle

Prabesh kumar Sahu, View ORCID ProfileSibasish Sahoo, View ORCID ProfileNamrata Chatterjee, View ORCID ProfileJitendra Majhi, View ORCID ProfileAtanu Kumar Dutta, Kalyan Goswami, Amit Pal
doi: https://doi.org/10.1101/2023.01.11.23284245
Prabesh kumar Sahu
1All India institute of medical sciences, Kalyani, West Bengal, India
MBBS 2nd year
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sibasish Sahoo
1All India institute of medical sciences, Kalyani, West Bengal, India
MD Biochemistry
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Sibasish Sahoo
  • For correspondence: drsibasish18{at}gmail.com sibasish.biochem{at}aiimskalyani.edu.in
Namrata Chatterjee
1All India institute of medical sciences, Kalyani, West Bengal, India
MSc Medical Biochemistry
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Namrata Chatterjee
Jitendra Majhi
1All India institute of medical sciences, Kalyani, West Bengal, India
MD Community Medicine
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Jitendra Majhi
Atanu Kumar Dutta
1All India institute of medical sciences, Kalyani, West Bengal, India
MD Biochemistry
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Atanu Kumar Dutta
Kalyan Goswami
1All India institute of medical sciences, Kalyani, West Bengal, India
MD Biochemistry
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Amit Pal
1All India institute of medical sciences, Kalyani, West Bengal, India
PhD Biochemistry
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Background The collection of blood samples in different vacutainers can affect the result of serum lithium estimation due to the presence of distinct additives added in the blood collection vacutainer for enhancing the clot formation process. The presence of these additives has proven to interfere with laboratory results of biochemical analytes. In this case, both the pre-analytical and the analytical phases have a significant impact on the accuracy and precision of the test result. Thus, it has become a challenge for the lab physician to estimate lithium in any clinical laboratory setup.

Materials and Methods In total, 100 patient samples were collected and paired into clot activator vacutainers and plain glass vials. Both the paired collecting tubes after centrifugation were processed immediately via Vitros 4600 analyzer working on the principle of reflectance photometry. Both the paired tubes were stored at 2-8 degrees centigrade and were further analyzed, at 24 and 48 hours respectively, from the time of their collection. The statistical analysis was done in IBM® SPSS® software version 23.

Results There was a significant difference in the lithium values obtained from clot activator vacutainers in comparison to glass vial. The difference between the measurements of the lithium levels was statistically tested by ‘t’ test where it was observed that the lithium measurements by the two different collecting tubes differed significantly with a Confidence Interval of 0.03 to 0.06 implying the level of agreement of both the methods are not similar. But there was no statistical difference in the lithium values estimated at 24 hours and 48 hours of collection.

Conclusion In this study, lithium levels measured by clot-activated vacutainers are found to be low as compared to lithium levels measured through glass vials. There is no apparent change in lithium values obtained at 1hr, 24hrs & 48hrs from their collection, when measured from the glass vials and the clot-activated vacutainers respectively, by the Vitros 4600 dry chemistry analyzer.

Summary Statement Serum Lithium estimation in clincal laboratory may be done different methodologies, but the result may vary due to change in principle of investigation and the pre analytical and analytical interferences.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

This study did not receive any funding

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Institutional Affiliation: All India Institute of Medical Sciences, Kalyani. Approval of the Ethics Committee of the All India Institute of Medical Sciences Kalyani was obtained. Reference Number: IEC/AIIMS/KAlyani/Meeting/2022/47

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.

Yes

Footnotes

  • Email id: prabesh.mbbs-2020{at}aiimskalyani.edu.in

  • Email id: drsibasish18{at}gmail.com

  • Email id: namrataranichatterjee{at}gmail.com

  • Email id: Jitendra.cmfm{at}aiimskalyani.edu.in

  • Email id: atanu.biochem{at}aiimskalyani.edu.in

  • Email.id: kalyan.biochem{at}aiimskalyani.edu.in

  • Email.id: amit.biochem{at}aiimskalyani.edu.in

Data Availability

All data produced in the present study are available upon reasonable request to the authors

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted January 14, 2023.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Comparative evaluation of serum lithium estimation in serum samples using plain glass vial and serum clot activator vacutainer by reflectance photometry principle
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Comparative evaluation of serum lithium estimation in serum samples using plain glass vial and serum clot activator vacutainer by reflectance photometry principle
Prabesh kumar Sahu, Sibasish Sahoo, Namrata Chatterjee, Jitendra Majhi, Atanu Kumar Dutta, Kalyan Goswami, Amit Pal
medRxiv 2023.01.11.23284245; doi: https://doi.org/10.1101/2023.01.11.23284245
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Comparative evaluation of serum lithium estimation in serum samples using plain glass vial and serum clot activator vacutainer by reflectance photometry principle
Prabesh kumar Sahu, Sibasish Sahoo, Namrata Chatterjee, Jitendra Majhi, Atanu Kumar Dutta, Kalyan Goswami, Amit Pal
medRxiv 2023.01.11.23284245; doi: https://doi.org/10.1101/2023.01.11.23284245

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Health Systems and Quality Improvement
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)