Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Inter-scanner Aβ-amyloid PET harmonization using barrel phantom spatial resolution matching

Gihan P. Ruwanpathirana, Robert C. Williams, View ORCID ProfileColin L. Masters, View ORCID ProfileChristopher C. Rowe, View ORCID ProfileLeigh A. Johnston, View ORCID ProfileCatherine E. Davey
doi: https://doi.org/10.1101/2023.07.16.23292733
Gihan P. Ruwanpathirana
1Department of Biomedical Engineering, The University of Melbourne, Melbourne, VIC, Australia
2Melbourne Brain Centre Imaging Unit, The University of Melbourne, Melbourne, VIC, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Robert C. Williams
2Melbourne Brain Centre Imaging Unit, The University of Melbourne, Melbourne, VIC, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Colin L. Masters
3Florey Institute of Neurosciences and Mental Health, The University of Melbourne, Melbourne, VIC, Australia
4The Australian Dementia Network (ADNET), Melbourne, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Colin L. Masters
Christopher C. Rowe
3Florey Institute of Neurosciences and Mental Health, The University of Melbourne, Melbourne, VIC, Australia
4The Australian Dementia Network (ADNET), Melbourne, Australia
5Department of Molecular Imaging & Therapy, Melbourne, Austin Health, VIC, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Christopher C. Rowe
Leigh A. Johnston
1Department of Biomedical Engineering, The University of Melbourne, Melbourne, VIC, Australia
2Melbourne Brain Centre Imaging Unit, The University of Melbourne, Melbourne, VIC, Australia
6Graeme Clarke Institute for Biomedical Engineering, the University of Melbourne
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Leigh A. Johnston
Catherine E. Davey
1Department of Biomedical Engineering, The University of Melbourne, Melbourne, VIC, Australia
2Melbourne Brain Centre Imaging Unit, The University of Melbourne, Melbourne, VIC, Australia
6Graeme Clarke Institute for Biomedical Engineering, the University of Melbourne
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Catherine E. Davey
  • For correspondence: catherine.davey{at}unimelb.edu.au
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

The standardized uptake value ratio (SUVR) is used to measure Aβ uptake in PET images of the brain. Variations in PET scanner technologies and image reconstruction techniques can lead to variability in images acquired from different scanners. This poses a challenge for Aβ-PET studies conducted across multiple centers. The aim of harmonization is to achieve consistent Aβ-PET measurements across scanners. In this study, the procedure of matching the spatial resolution of a barrel phantom measured in each PET scanner is proposed as a method of Aβ-PET harmonization, validated using subject data.

Methods Three different PET scanners were used: the Siemens Biograph Vision 600, Siemens Biograph mCT, and Philips Gemini TF64. A total of five, eight, and five subjects were each scanned twice with [18F]-NAV4694 across Vision-mCT, mCT-Philips, and Vision-Philips scanner pairs. The Vision and mCT scans were reconstructed using various iterations, subsets, and post-reconstruction Gaussian smoothing, while one reconstruction configuration was used for the Philips scans. The full-width at half-maximum (FWHM) of each reconstruction configuration was calculated using [18F]-filled barrel phantom scans with the SNMMI phantom analysis toolkit. Regional SUVRs were calculated from 72 brain regions using the AAL3 atlas for each subject and reconstruction configuration. Statistical similarity between SUVRs was assessed using paired (within subject) t-tests for each pair of reconstructions across scanners; the higher the p-value, the greater the similarity between the SUVRs.

Vision-mCT harmonization maximal statistical similarity (i.e., p-value) between regional SUVRs was achieved using a 4.10 mm FWHM Vision reconstruction with a 4.30 mm FWHM mCT reconstruction.

Philips-mCT harmonization maximal statistical similarity between regional SUVRs was achieved using an 8.2 mm FWHM Philips reconstruction with a 9.35 mm FWHM mCT reconstruction.

Philips-Vision harmonization a 9.1 mm FWHM Vision reconstruction had maximum statistical similarity with regional SUVRs from an 8.2mm FWHM Philips reconstruction. Reconstruction pairs that maximized statistical similarity, and supported a null hypothesis of being drawn from the same distribution, were selected as harmonised for each scanner pair.

Conclusion Using data obtained from three sets of participants, each scanned on a different pair of PET scanners, using reconstruction configurations with matched barrel phantom spatial resolutions, we have demonstrated that Aβ-PET quantitation can be harmonised across scanners, producing SUVR values statistically likely to be drawn from the same distribution. This finding is encouraging for the use of different PET scanners in multi-centre trials, or updates during longitudinal studies.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

This study was funded by the Australian Research Council and the National Health and Medical Research Council .

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Ethics approval and consent to participate in this study were approved by the Austin Health Human Research Ethics Committee (HREC/18/Austin/201)

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Footnotes

  • First author: Gihan Ruwanpathirana (student), gruwanpathir{at}student.unimelb.edu.au

  • Financial support: The research was supported by NHMRC and NIH grants. *

Data Availability

All data produced in the present study are available upon reasonable request to the authors

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted July 18, 2023.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Inter-scanner Aβ-amyloid PET harmonization using barrel phantom spatial resolution matching
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Inter-scanner Aβ-amyloid PET harmonization using barrel phantom spatial resolution matching
Gihan P. Ruwanpathirana, Robert C. Williams, Colin L. Masters, Christopher C. Rowe, Leigh A. Johnston, Catherine E. Davey
medRxiv 2023.07.16.23292733; doi: https://doi.org/10.1101/2023.07.16.23292733
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Inter-scanner Aβ-amyloid PET harmonization using barrel phantom spatial resolution matching
Gihan P. Ruwanpathirana, Robert C. Williams, Colin L. Masters, Christopher C. Rowe, Leigh A. Johnston, Catherine E. Davey
medRxiv 2023.07.16.23292733; doi: https://doi.org/10.1101/2023.07.16.23292733

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Radiology and Imaging
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)