Abstract
Many clinical applications require medical image harmonization to combine and normalize images from different scanners or protocols. This paper introduces a Transformer-based MR image harmonization method. Our proposed method leverages the self-attention mechanism of the Transformer to learn the complex relationships between image patches and effectively transfer the imaging characteristics from a source image domain to a target image domain. We evaluate our approach to state-of-the-art methods using a publicly available dataset of brain MRI scans and show that it provides superior quantitative metrics and visual quality. Furthermore, we demonstrate that the proposed approach is highly resistant to fluctuations in image modality, resolution, and noise. Overall, the experiment results indicate that our approach is a promising method for medical image harmonization that can improve the accuracy and reliability of automated analysis and diagnosis in clinical settings.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work is supported by NSFC 62103116 and Heilongjiang Provincial NSF LH2022F016.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The study used (or will use) ONLY openly available human data that were originally located at: www.adni-info.org.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
All data produced in the present work are contained in the manuscript