Abstract
This study investigates the quality of peak oxygen consumption (VO2peak) prediction based on cardiac and respiratory parameters calculated from warmup and submaximal stages of treadmill cardiopulmonary exercise test (CPET) using machine learning (ML) techniques and assesses the importance of respiratory parameters for the prediction outcome. The database consists of the following parameters: heart rate (HR), respiratory rate (RespRate), pulmonary ventilation (VE), oxygen consumption (VO2) and carbon dioxide production (VCO2) obtained from 369 treadmill CPETs. Combinations of features calculated based on the HR, VE and RespRate time-series from different stages of CPET were used to create 11 datasets for VO2peak prediction. Thirteen ML algorithms were employed, and model performances were evaluated using cross-validation with mean absolute percentage error (MAPE), R2 score, mean absolute error (MAE), and root mean squared error (RMSE) calculated after each iteration of the validation. The results demonstrated that incorporating respiratory-based features improves the prediction of VO2peak. The best results in terms of R2 score (0.47) and RMSE (5.78) were obtained for the dataset which included both cardiac- and respiratory-based features from CPET up to 85% of age-predicted HRmax, while the best results in terms of MAPE (10.5%) and MAE (4.63) were obtained for the dataset containing cardiorespiratory features from the last 30 seconds of warmup. The study showed the potential of using ML models based on cardiorespiratory features from submaximal tests for prediction of VO2peak and highlights the importance of the monitoring of respiratory signals, enabling to include respiratory parameters into the analysis. Presented approach offers a feasible alternative to direct VO2peak measurement, especially when specialized equipment is limited or unavailable.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
Research was founded by POB Biotechnology and biomedical engineering of Warsaw University of Technology within the Excellence Initiative: Research University (IDUB) programme. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The database used in this study was created based on the study protocols, which were approved by the Research Ethics Committee of the University of Málaga.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
All files are available from the Physionet database: https://physionet.org/content/treadmill-exercise-cardioresp/1.0.1/ (DOI: 10.13026/7ezk-j442)
https://physionet.org/content/treadmill-exercise-cardioresp/1.0.1/