Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Micrometer-thick, porous, nanocomposite coating for electrochemical sensors with exceptional antifouling and electroconducting properties

Jeong-Chan Lee, Su Yeong Kim, Jayeon Song, Hyowon Jang, Hanul Kim, Siyoung Q. Choi, Sunjoo Kim, Pawan Jolly, Taejoon Kang, Steve Park, Donald E. Ingber
doi: https://doi.org/10.1101/2023.09.23.23296012
Jeong-Chan Lee
1Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
2Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Su Yeong Kim
1Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jayeon Song
3Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 34141, Republic of Korea
4Center for Systems Biology, Massachusetts General Hospital Research Institute, Boston, MA 02114, USA
5Department of Radiology, Harvard Medical School, Boston, MA 02114, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hyowon Jang
3Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 34141, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hanul Kim
6Department of Chemical and Biomolecular Engineering, KAIST, Daejeon 34141, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Siyoung Q. Choi
6Department of Chemical and Biomolecular Engineering, KAIST, Daejeon 34141, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sunjoo Kim
7Department of Laboratory Medicine, Gyeongsang National University Hospital, Gyeongsang National University College of Medicine, Jinju-si, Gyeongsangnam-do 52727, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pawan Jolly
2Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Taejoon Kang
3Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 34141, Republic of Korea
8School of Pharmacy, Sungkyunkwan University (SKKU), Suwon-si, Gyeongi-do 16419, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: don.ingber{at}wyss.harvard.edu stevepark{at}kaist.ac.kr kangtaejoon{at}kribb.re.kr
Steve Park
1Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: don.ingber{at}wyss.harvard.edu stevepark{at}kaist.ac.kr kangtaejoon{at}kribb.re.kr
Donald E. Ingber
2Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
9Vascular Biology Program and Department of Surgery, Boston Children’s Hospital and Harvard Medical School, Boston, MA 02115, USA
10Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA 02115, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: don.ingber{at}wyss.harvard.edu stevepark{at}kaist.ac.kr kangtaejoon{at}kribb.re.kr
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

ABSTRACT

Development of coating technologies for electrochemical sensors that consistently exhibit antifouling activities when exposed to diverse and complex biological environments over extended time is vital for development more effective medical devices and diagnostics. Here, we describe a micrometer-thick, porous nanocomposite coating with both exceptional antifouling and electroconducting properties that greatly enhance the sensitivity of electrochemical sensors. Nozzle-assisted printing of oil-in-water emulsion is used to create a 1 micrometer thick coating composed of cross-linked albumin with interconnected pores, which also contains electroconducting gold nanowires. Using this approach, the antifouling conductive coating can be deposited only on the surface of the working electrode, and not on the reference and counter electrodes, which greatly facilitates the fabrication and functionality of multiplexed electrochemical sensors. The layer effectively resists biofouling and maintains rapid electron transfer kinetics for over one month when exposed directly to complex biological fluids, including serum and nasopharyngeal secretions. Compared to previously described thinner (nanometer thick) antifouling electroconductive coating made with drop casting or a spin coating of the same thickness, the nozzle-printed sensors coated with this thick porous nanocomposite exhibited sensitivities that were enhanced by 3.75- to 17-fold when three different target biomolecules were tested. As a result, emulsion-coated, multiplexed electrochemical sensors coated were able to carry out simultaneous detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid, antigen, and host antibody in clinical specimens with high sensitivity and specificity. This thick porous emulsion coating technology may provide a way to address hurdles currently restricting the application of electrochemical sensors for point-of-care (POC) diagnostic applications, as well as their use in implantable devices and other healthcare monitoring systems.

Competing Interest Statement

J.C.L, P.J., S.P., and D.E.I. are listed as inventors on patents describing this technology.

Funding Statement

This work was supported by the funding from the Wyss Institute at Harvard University, Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant funded by the Korea Government (MOTIE) (no. 20183010014470). This work also supported by the National Research Foundation of Korea (NRF-2021M3H4A1A03049049 and NRF-2022R1A2C2006076).

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

Institutional Review Board (IRB) of Gyeongsang National University College of Medicine in Changwon, Korea gave ethical approval for this work (IRB approval number: 2022-10-012)

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

All data needed to evaluate the conclusions of this work can be found in the paper and/or the Supplementary Materials.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted September 25, 2023.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Micrometer-thick, porous, nanocomposite coating for electrochemical sensors with exceptional antifouling and electroconducting properties
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Micrometer-thick, porous, nanocomposite coating for electrochemical sensors with exceptional antifouling and electroconducting properties
Jeong-Chan Lee, Su Yeong Kim, Jayeon Song, Hyowon Jang, Hanul Kim, Siyoung Q. Choi, Sunjoo Kim, Pawan Jolly, Taejoon Kang, Steve Park, Donald E. Ingber
medRxiv 2023.09.23.23296012; doi: https://doi.org/10.1101/2023.09.23.23296012
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Micrometer-thick, porous, nanocomposite coating for electrochemical sensors with exceptional antifouling and electroconducting properties
Jeong-Chan Lee, Su Yeong Kim, Jayeon Song, Hyowon Jang, Hanul Kim, Siyoung Q. Choi, Sunjoo Kim, Pawan Jolly, Taejoon Kang, Steve Park, Donald E. Ingber
medRxiv 2023.09.23.23296012; doi: https://doi.org/10.1101/2023.09.23.23296012

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Infectious Diseases (except HIV/AIDS)
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)