Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

The Effects of Decreased Frame Rate During Cardiac Catheterization on Patient and Radiation Safety Outcomes

Al-Ameen Oredegbe, Matthew Derakhshesh, Ravi Vuthoori, Mikhail Torosoff, Anthony Nappi, Neil Yager
doi: https://doi.org/10.1101/2023.10.04.23296575
Al-Ameen Oredegbe
1Albany Medical Center
MBBChBAO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: oredega{at}amc.edu
Matthew Derakhshesh
1Albany Medical Center
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ravi Vuthoori
1Albany Medical Center
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mikhail Torosoff
1Albany Medical Center
MD, PhD, FACC, FASE
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Anthony Nappi
1Albany Medical Center
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Neil Yager
1Albany Medical Center
DO, FACC
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Objective Coronary artery disease (CAD) is an important cause of morbidity and mortality all over the world. Cardiac catheterization is one of the most important treatment modalities in managing CAD. Unfortunately, cardiac catheterization is associated with significant ionizing radiation exposure to both patients and personnel. This study aimed to compare the safety and efficacy of a lower video frame rate of 7.5-fps compared with the standard frame rate of 15-fps.

Materials and Methods We retrospectively collected and reviewed data from 84 cardiac catheterizations performed between January and February 2020 at a single tertiary center. The patients were divided into two groups based on frame rate: 15-fps (n=42) and 7.5-fps (n=42). We compared the two groups in terms of demographic data, procedural characteristics, radiation dose, and patient outcomes.

Results Cumulative air kerma was significantly lower in the 7.5-fps group (266.576 mGy) compared to the 15-fps group (524.140 mGy), p=0.0018. Similarly, total dose area product was lower in the 7.5-fps group (15335.617 mGy × cm2 compared to the 15-fps group (34784.095 mG × cm2), p = 0.0003. Despite this, total fluoroscopic time did not differ between the two groups 7.74 minutes in the 15-fps group and 8.462 minutes in the 7.5-fps group, p = 0.4023). In addition, 30-day mortality 0% in both groups and there were no differences in the number of repeat PCIs performed within 30 days (6 in 7.5-fps and 3 in the 15-fps group), p = 0.2899.

Conclusion During cardiac catheterization, a fluoroscopy rate of 7.5-fps is associated with lower radiation dose compared to 15-fps without an associated increase in fluoroscopy time, mortality or repeat PCI. Therefore, interventionalists should consider using a fluoroscopy rate of 7.5-fps during cardiac catheterization.

Competing Interest Statement

The authors have declared no competing interest.

Clinical Trial

This was a retrospective study.

Funding Statement

No external funding was received.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

This project was approved by the Albany Medical Center Institutional Review Board (IRB).

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

The authors confirm that the data supporting the findings of this study are available within the article.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted October 05, 2023.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
The Effects of Decreased Frame Rate During Cardiac Catheterization on Patient and Radiation Safety Outcomes
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
The Effects of Decreased Frame Rate During Cardiac Catheterization on Patient and Radiation Safety Outcomes
Al-Ameen Oredegbe, Matthew Derakhshesh, Ravi Vuthoori, Mikhail Torosoff, Anthony Nappi, Neil Yager
medRxiv 2023.10.04.23296575; doi: https://doi.org/10.1101/2023.10.04.23296575
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
The Effects of Decreased Frame Rate During Cardiac Catheterization on Patient and Radiation Safety Outcomes
Al-Ameen Oredegbe, Matthew Derakhshesh, Ravi Vuthoori, Mikhail Torosoff, Anthony Nappi, Neil Yager
medRxiv 2023.10.04.23296575; doi: https://doi.org/10.1101/2023.10.04.23296575

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Cardiovascular Medicine
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)