ABSTRACT
Introduction Popliteal artery aneurysms (PAAs) are associated with high morbidity and mortality and current Society for Vascular Surgery (SVS) recommend operative repair for PAAs with a diameter greater than 20 mm, which is based on limited evidence. To help risk stratify patients for surgery, our aim was to identify anatomic characteristics of PAA associated with limb threatening and thromboembolic events (TEs).
Methods A retrospective multi-institutional cohort was queried for all patients with a PAA from 2008 to 2022. Symptom status at the time of presentation was divided into three categories: symptomatic PAA with documented claudication or chronic limb ischemia (CLI), limb threatening PAA with a TE, acute limb ischemia, or rupture, and asymptomatic PAA without symptoms or limb threatening events. Patient and anatomic factors based on duplex ultrasound (DUS) were evaluated as potential predictors of symptom groups and thresholds of anatomic variables were identified using receiver operating characteristic curves.
Results There were 470 PAAs identified in 331 patients. The mean age was 74 years at diagnosis, 94% of patients were white, and 97% of patients were male. Cardiovascular comorbidities were prevalent in and similar between all patient groups studied, and almost all patients were on anticoagulation or antiplatelet therapy at the time of diagnosis, at 96%. The most common concurrent aneurysm was abdominal aortic aneurysm (62%). Patient comorbidities were not associated with symptom status. PAAs with a higher percent thrombus burden were 18 times more likely to experience a limb threatening event and 24 times more likely to experience a TE. A largest diameter threshold of 20.4 mm was predictive of a TE (sensitivity 78.1%, specificity 40.5%), but percent thrombus threshold of 62% outperformed largest diameter as a predictor of a TE (sensitivity of 81.3%, specificity 52.0%). Percent thrombus threshold of 73% also predicted limb threatening events (sensitivity 65.7%, specificity 69.7%).
Conclusion A PAA diameter greater than 20.4 mm was predictive of TEs, which is in agreement with clinical practice guidelines. However, percent thrombus greater than 62% outperformed largest diameter as a predictor of a TE. This analysis supports the use of size greater than 20.4 mm and 62% thrombus in identifying high risk PAAs that warrant repair.
Competing Interest Statement
The authors have declared no competing interest.
Clinical Trial
This was not a clinical trial
Funding Statement
This research was not supported by funding from any grant.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Not Applicable
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The Mass General Brigham Human Research Committee Institutional Review Board approved the study protocol for patients >18 years of age and patient consent to participate was waived (IRB # 2019P003163).
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Not Applicable
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Not Applicable
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Not Applicable
Data Availability
Data that were used in this study are available on request from the senior author (A.D.). Code to perform analyses in this manuscript are available from the authors upon request (A.D.).