Abstract
Background Low-voltage areas have been used as atrial structural substrates in estimating fibrotic degeneration in patients with atrial fibrillation (AF). The high-resolution maps obtained by recently developed mapping catheters allow the visualization of several functional abnormalities.
Objectives We investigated the association between left atrial (LA) functional abnormal findings on a high-resolution substrate map and AF recurrence in patients who underwent pulmonary vein isolation without any additional LA substrate ablation.
Methods One hundred consecutive patients who underwent second ablation for AF (paroxysmal, 48%; persistent, 52%) were considered for enrollment. Patients with extra-pulmonary-vein LA substrate ablation during the initial and second ablation were excluded. LA mapping was performed using a 64-pole mini-basket catheter on the Rhythmia mapping system. Patients were followed for 2 years.
Results AF recurrence developed in 39 (39%) patients. On the high-resolution substrate map, AF recurrence was associated with the presence of the following findings: low-voltage areas (<1.0 mV, >5cm2; hazard ratio [HR]=2.53; 95% confidence interval [CI]=1.30-4.93; p<0.006), fractionated-electrogram areas (≥5 peaks, >5cm2; HR=2.15, 95%CI=1.10-4.19; p=0.025), LA conduction time of >130 msec (HR=3.11, 95%CI=1.65-5.88, p<0.0001), deceleration zone (≥5 isochrones/cm2; HR=1.97, 95%CI=1.04-3.37, p=0.039), and multiple septal breakout points (HR=3.27, 95%CI=1.50-7.16, p=0.003). Accumulation of these risk factors increased AF recurrence in a stepwise manner, with an HR=1.90, 95%CI=1.44-2.52, p<0.00001 for each additional risk factor.
Conclusion A high-resolution map revealed new LA functional substrates associated with AF recurrence. Implementation of functional substrates may improve the prediction of AF recurrence after ablation, and possibly aid the development of tailored AF ablation strategies.
Study design, representative maps demonstrating abnormal substrates, and AF recurrence rates stratified by the number of risk factors are shown. Accumulation of these risk factors increased AF recurrence rates in a stepwise manner with an HR = 1.90, 95% CI = 1.44 - 2.52, p<0.00001, for 1 risk increase. AF indicates atrial fibrillation; HR, hazard ratio; CI, confidence interval.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
None
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Kansai Rosai Hospital ethics committee
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
Data will be available on request to the corresponding author.