ABSTRACT
Background Effective detection of early lung disease in cystic fibrosis (CF) is critical to understanding early pathogenesis and evaluating early intervention strategies. We aimed to compare ability of several proposed sensitive functional tools to detect early CF lung disease as defined by CT structural disease in school aged children.
Methods 50 CF subjects (mean±SD 11.2±3.5y, range 5-18y) with early lung disease (FEV1≥70% predicted: 95.7±11.8%) performed spirometry, Multiple breath washout (MBW, including trapped gas assessment), oscillometry, cardiopulmonary exercise testing (CPET) and simultaneous spirometer-directed low-dose CT imaging. CT data were analysed using well-evaluated fully quantitative software for bronchiectasis and air trapping (AT).
Results CT bronchiectasis and AT occurred in 24% and 58% of patients, respectively. Of the functional tools, MBW detected the highest rates of abnormality: Scond 82%, MBWTG RV 78%, LCI 74%, MBWTG IC 68% and Sacin 51%. CPET VO2peak detected slightly higher rates of abnormality (9%) than spirometry (FEV1/FVC 8%, FEF25-75 8%, FEV1 2%). For oscillometry AX (14%) performed better than Rrs (2%) whereas Xrs and R5-19 failed to detect any abnormality. LCI and Scond correlated with bronchiectasis (r=0.55-0.64, p<0.001) and AT (r=0.73-0.74, p<0.001). MBW-assessed trapped gas was detectable in 92% of subjects and concordant with CT-assessed AT in 74%.
Conclusions Significant structural and functional deficits occur in early CF lung disease, as detected by CT and MBW. For MBW, additional utility, beyond that offered by LCI, was suggested for Scond and MBW-assessed gas trapping. Our study reinforces the complementary nature of these tools and the limited utility of conventional oscillometry and CPET in this setting.
AUTHOR CONTRIBUTIONS
Conception and design: KB, OW, MOW, BB, TER, PG, DF, HS, PR
Acquisition, analysis and interpretation of data: KB, OW, CB, AB, RF, PG, AM, HS, BK, MOW, LY, CG, BB, TER, PR
Writing the manuscript or revising it critically for important intellectual content: KB, OW, CB, AB, RF, AM, BK, GJ, NC, PG, DF, HS, CG, MOW, BB, TER, PR
HIGHLIGHTS
In early lung disease, multiple breath washout and CT are complementary tools
MBW and CT detect more abnormality than oscillometry, CPET and spirometry
Sensitivity of MBW to detect abnormality can be increased by Scond and MBW-assessed trapped gas
GRANT SUPPORT Australian Cystic Fibrosis Research Trust: 2018 Innovation Grant. This study was supported by grants from the German Federal Ministry of Education and Research (82DZL004A1) (to OW, MOW).
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
A 2018 Australian CF Research Trust Innovation Grant funded this study.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Ethics committee approval from the Sydney Children's Hospitals Network Human Research Ethics Committee (SCHN HREC, ethics approval 18/SCHN/469) and written informed consent/assent was obtained from all parents/guardians and children
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
All data produced in the present study are available upon reasonable request to the authors