Abstract
Introduction Screening and diagnostic mammography are associated with some risk of radiation-induced breast cancer. This study was conducted to establish the National Diagnostic Reference Levels (NDRLs) for digital diagnostic and screening mammography in Uganda to achieve breast radiation dose optimization.
Methods A cross-sectional study was conducted among female participants recruited by a consecutive sampling from three selected Hospitals with digital mammography in Uganda. The study variables extracted from the mammography machines were exposure factors, compressed breast thickness (CBT), and Average Glandular Dose (AGD) of two standard mammogram views. The stratified National DRL was derived by calculating 75th percentile of the AGD across all the samples at various CBT ranges for both screening and diagnostic mammography in craniocaudal (CC) and mediolateral oblique (MLO) views.
Results We included 300 participants with mean ages of 50.28±9.32 and 47.45±13.45 years for the screening and diagnostic mammography, respectively. There were statistically significant positive correlations between AGD and exposures factors (mAs, kVp) (all p-values<0.0001). For screening mammography, mAs demonstrated a strong positive correlation (r = 0.8369 in CC, 0.8133 in MLO), whereas kVp showed positive correlation with relatively lower coefficients (r = 0.3700 in CC, 0.3080 in MLO). In diagnostic mammography, mAs exhibited an even stronger positive correlation (r = 0.8987 in CC, 0.8762 in MLO), and kVp maintained a positive correlation with somewhat lower coefficients (r = 0.4954 in CC, 0.3597 in MLO). In screening mammography, for CBT within the range of (7-39)mm, the NDRLs were (1.5mGy, 1.66mGy) in CC) and MLO views. For CBT in the range of (40-59)mm, the NDRLs were (1.78mGy, 1.87mGy), and for CBT in the range of (60-99)mm, the NDRLs were (2.18mGy, 2.22mGy). For diagnostic mammography, the NDRLs were established as (1.7mGy, 1.91mGy), (2.00mGy, 2.09mGy), and (2.63mGy, 2.81mGy) for CBT ranges of (7-39)mm, (40-59)mm, and (60-99)mm, respectively.
Conclusion The NDRLs for digital screening and diagnostic mammography in Uganda have been proposed for the first time. The NDRL values in mammography should be specific to CBT ranges and mammographic views for both diagnostic and screening mammography.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The author(s) received no specific funding for this work.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Not Applicable
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Ethical approval to conduct the study was obtained from the Institutional Review Board (IRB) of the School of Medicine, Makerere University College of health sciences (protocol reference number: Mak-SOMREC-2023-562).
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Not Applicable
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Not Applicable
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Not Applicable
Data Availability
All relevant data are within the manuscript and its Supporting Information files.