Assessing quadriceps strength in patellofemoral pain patients: A study on the reliability and validity of a low-cost load-cell for clinical practice

Germari Deysel, Mariaan van Aswegen, View ORCID ProfileMark Kramer
doi: https://doi.org/10.1101/2024.02.01.24301977
Germari Deysel
1Physical Activity, Sport, and Recreation (PhasRec) Research Focus Area, North-West University, Potchefstroom, North West Province, South Africa
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mariaan van Aswegen
1Physical Activity, Sport, and Recreation (PhasRec) Research Focus Area, North-West University, Potchefstroom, North West Province, South Africa
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mark Kramer
1Physical Activity, Sport, and Recreation (PhasRec) Research Focus Area, North-West University, Potchefstroom, North West Province, South Africa
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Mark Kramer
  • For correspondence: mark.kramer{at}nwu.ac.za
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Background Patellofemoral pain (PFP) is a common knee complaint affecting diverse populations both acutely and chronically. Quadriceps muscle weakness is one possible aetiology, but current devices for measuring muscle strength (isokinetic dynamometer and hand-held dynamometers) are frequently too expensive for practitioners, especially in under-resourced settings. There is a need to evaluate a low-cost device to manage rehabilitation of people with PFP.

Methods Isometric quadriceps strength of participants aged 18-35 years (total [n = 33], control group [n = 17] and PFP group [n = 16]) were evaluated on an isokinetic dynamometer and a low-cost load cell at baseline and after an 8-week non-standardised intervention for validity scores.

Results The load cell showed high absolute and relative reliability (intraclass correlation coefficient = 0.89-0.99; typical error of measurement = 3.9-10.4%). Clinically meaningful difference scores (12.2-45 Nm) were greater than the typical error of measurement, implying sufficient sensitivity of the load cell to measure true changes in isometric quadricep strength. Strong to very strong correlations were evident between the load cell and isokinetic dynamometer torque measurements (r = 0.88-0.90, SEE = 0.05-0.07 Nm), but slope values (β = 0.65-0.77) indicated that torque from the load cell was typically lower than that obtained from the isokinetic dynamometer. An average systematic bias of 16.3-28.8 Nm was evident in favour of the isokinetic dynamometer, with no statistically significant between-group differences being noted between the baseline and follow-up testing.

Conclusion The load cell is a reliable instrument, sensitive enough to detect clinically meaningful differences in quadriceps strength in healthy individuals and those with PFP. The load cell lacks validity and cannot replace isokinetic dynamometry. Given the low cost and excellent reliability, the load cell can be a valuable tool to assess quadriceps muscle deficits and track rehabilitation progress in people with PFP.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

The author(s) received no specific funding for this work.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

The Human Research Ethics Committee of the North West University gave ethical approval for this work (ethics approval number: NWU-00163-22-A1).

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

https://doi.org/10.7910/DVN/N1SSPT

https://doi.org/10.7910/DVN/N1SSPT

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted February 03, 2024.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Assessing quadriceps strength in patellofemoral pain patients: A study on the reliability and validity of a low-cost load-cell for clinical practice
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Assessing quadriceps strength in patellofemoral pain patients: A study on the reliability and validity of a low-cost load-cell for clinical practice
Germari Deysel, Mariaan van Aswegen, Mark Kramer
medRxiv 2024.02.01.24301977; doi: https://doi.org/10.1101/2024.02.01.24301977
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Assessing quadriceps strength in patellofemoral pain patients: A study on the reliability and validity of a low-cost load-cell for clinical practice
Germari Deysel, Mariaan van Aswegen, Mark Kramer
medRxiv 2024.02.01.24301977; doi: https://doi.org/10.1101/2024.02.01.24301977

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Rehabilitation Medicine and Physical Therapy
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)