Diagnostic accuracy of the Point-of-Care Standard G6PD test™ (SD Biosensor) for Glucose-6-phosphate dehydrogenase deficiency: a systematic review of the literature

View ORCID ProfileJuan Camilo Martínez, View ORCID ProfileViviana Vélez-Marín, View ORCID ProfileMary Lopez-Perez, View ORCID ProfileDaniel Felipe Patiño, View ORCID ProfileIvan D. Florez
doi: https://doi.org/10.1101/2024.02.10.24302326
Juan Camilo Martínez
1Unit of evidence and deliberation for decision making UNED, Medical Research Institute, School of Medicine, University of Antioquia UdeA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Juan Camilo Martínez
  • For correspondence: ivan.florez{at}udea.edu.co
Viviana Vélez-Marín
1Unit of evidence and deliberation for decision making UNED, Medical Research Institute, School of Medicine, University of Antioquia UdeA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Viviana Vélez-Marín
Mary Lopez-Perez
2Centre for Medical Parasitology, Department for Immunology and Microbiology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Mary Lopez-Perez
Daniel Felipe Patiño
1Unit of evidence and deliberation for decision making UNED, Medical Research Institute, School of Medicine, University of Antioquia UdeA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Daniel Felipe Patiño
Ivan D. Florez
1Unit of evidence and deliberation for decision making UNED, Medical Research Institute, School of Medicine, University of Antioquia UdeA
3Department of Pediatrics, School of Medicine, University of Antioquia UdeA, Av. St 70 No. 52-21, Medellin, Colombia
4School of Rehabilitation Science, McMaster University, Hamilton, Canada
5Pediatric Intensive Care Unit, Clinica Las Americas-AUNA, Medellin, Colombia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Ivan D. Florez
  • For correspondence: ivan.florez{at}udea.edu.co
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

Abstract

Glucose-6-Phosphate Dehydrogenase deficiency (G6PDd) is a common genetic enzymopathy that can induce hemolysis triggered by various factors, including some anti-malarial drugs. Although many Point-of-Care (PoC) tests, such as STANDARD G6PDTM manufactured by SD biosensor (StandG6PD-BS), are available to detect G6PDd, its pooled diagnostic test accuracy (DTA) remains unknown. To estimate the DTA of StandG6PD-BS at various thresholds of G6PDd, we conducted a systematic review with a DTA meta-analysis, searching EMBASE, MEDLINE, and SciELO databases up to June 30, 2023. We included studies measuring G6PD activity using StandG6PD-BS (reference test) and spectrophotometry (gold standard) in patients suspected of having G6PDd. We assessed the risk of bias (RoB) of the studies using the QUADAS-2 tool and the certainty of evidence (CoE) with the GRADE approach. Our approach included the estimation of within-study DTA, a random-effect bivariate meta-analysis to determine the pooled sensitivity and specificity for 30%, 70%, and 80% enzyme levels’ thresholds, and a graphical analysis of the heterogeneity using crosshair and Confidence Regions on receiver operating characteristic (ROC) space plots. After screening 2,407 reports, we included four studies with 7,864 participants covering all thresholds. Two studies had high RoB in QUADAS-2 domains 2 and 3, and the others had low RoB. We also found low, moderate, and high heterogeneity at the 30%, 70%, and 80% thresholds, respectively. The pooled sensitivity was 99.1% (95%CI 96.9-99.7%, CoE: high), 95.7% (92.0-97.0%, high), and 90% (78.0-96.5%, low) for 30%, 70%, and 80% thresholds, respectively. The pooled specificity was 97.4% (95%CI 95.0; 98.4%, high); 92.9% (85.0-96.4%, high); and 89.0% (76.0-96.0%, moderate) for 30%, 70%, and 80% thresholds, respectively. In conclusion, StandG6PD-BS is a PoC test with high sensitivity and specificity to detect G6PDd at different thresholds.

Author summary Glucose-6-Phosphate Dehydrogenase deficiency (G6PDd) is a common genetic disease that can induce the destruction of red blood cells leading to anemia triggered by various factors, including some drugs used for malaria treatment. After a literature search in different databases up to January 31, 2023, we pooled diagnostic test accuracy of the Point-of-Care (PoC) STANDARD G6PDTM test manufactured by SD biosensor (StandG6PD-BS) used to identify the G6PDd. Although two of the four studies included showed a high Risk of Bias related to the index test and the reference standard domains of the QUADAS-2 tool, the pooled sensitivity and specificity for 30%, 70%, and 80% enzyme levels’ thresholds were around 90%, with better sensitivity and specificity values for the 30% threshold (99.1% and 97.4%) compared with 70% (95.7% and 92.9%) and 80% (90% and 89%) threshold. We found low, moderate, and high heterogeneity at the 30%, 70%, and 80% thresholds. In conclusion, StandG6PD-BS is a PoC test with high sensitivity and specificity to detect G6PDd at different thresholds.

Competing Interest Statement

The authors have declared no competing interest.

Clinical Protocols

https://www.crd.york.ac.uk/Prospero/display_record.php?RecordID=311085

Funding Statement

Yes

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

Data for the analyses was obtained from published studies. Additional data are available on request from the authors.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY 4.0 International license.
Back to top
PreviousNext
Posted February 11, 2024.
Download PDF

Supplementary Material

Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Diagnostic accuracy of the Point-of-Care Standard G6PD test™ (SD Biosensor) for Glucose-6-phosphate dehydrogenase deficiency: a systematic review of the literature
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Diagnostic accuracy of the Point-of-Care Standard G6PD test™ (SD Biosensor) for Glucose-6-phosphate dehydrogenase deficiency: a systematic review of the literature
Juan Camilo Martínez, Viviana Vélez-Marín, Mary Lopez-Perez, Daniel Felipe Patiño, Ivan D. Florez
medRxiv 2024.02.10.24302326; doi: https://doi.org/10.1101/2024.02.10.24302326
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Diagnostic accuracy of the Point-of-Care Standard G6PD test™ (SD Biosensor) for Glucose-6-phosphate dehydrogenase deficiency: a systematic review of the literature
Juan Camilo Martínez, Viviana Vélez-Marín, Mary Lopez-Perez, Daniel Felipe Patiño, Ivan D. Florez
medRxiv 2024.02.10.24302326; doi: https://doi.org/10.1101/2024.02.10.24302326

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Infectious Diseases (except HIV/AIDS)
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)