A computationally efficient method for dimensionality reduction in multi-channel spectral CT

View ORCID ProfileOlivia F. Sandvold, Roland Proksa, Heiner Daerr, Amy E. Perkins, Kevin M. Brown, Thomas Koehler, Ravindra M. Manjeshwar, View ORCID ProfilePeter B. Noël
doi: https://doi.org/10.1101/2024.02.18.24302905
Olivia F. Sandvold
1Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA
2Department of Bioengineering, University of Pennsylvania, Philadelphia, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Olivia F. Sandvold
  • For correspondence: sandvold{at}seas.upenn.edu
Roland Proksa
1Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Heiner Daerr
3Philips Innovative Technologies, Hamburg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Amy E. Perkins
4Philips Healthcare, Cleveland, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kevin M. Brown
4Philips Healthcare, Cleveland, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Thomas Koehler
3Philips Innovative Technologies, Hamburg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ravindra M. Manjeshwar
4Philips Healthcare, Cleveland, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Peter B. Noël
1Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Peter B. Noël
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Objective Multi-channel spectral CT technology holds the promise of measuring incoming X-rays across various energy spectrums, significantly enhancing iodine imaging performance. Nonetheless, it necessitates the reduction of data dimensions, such as condensing multiple energy bins, to ensure processing times remain within clinically acceptable limits and to maintain compatibility with traditional two-dimensional material decomposition methodologies. This study presents an optimization strategy designed to efficiently integrate multi-channel spectral CT data, aiming to minimize the anticipated noise in the iodine domain across different system parameters influencing channel content.

Approach The Cramer-Rao lower bound of variance (CRLB) was used to estimate the iodine domain noise for four two-input weighting schemes including kVp-switching compared to a four-input material decomposition noise estimate. Two of the four weighting schemes were optimized to contain weights that minimized the expected CRLB noise. A model of rapid kVp-switching x-ray tube and dual-layer detector were used to simulate acquisitions of a hybrid, combined technology multi-channel spectral CT system. The impact of the duty cycle ratio, or proportion of high kVp to low kVp, and the phantom size ranging from adult to pediatric were investigated.

Main Results The two-input weighting schemes with varying amounts of each spectral channel, optimized for low iodine noise, showed consistent low estimated noise performance within 0.27% difference to the ideal, four-input material decomposition results for all tested duty cycles in a standard adult-sized 300 mm water phantom. These schemes were always superior to kVp-switching regardless of duty cycle or phantom size. In the pediatric (150 mm) and large adult (400 mm) phantom cases, the two-input weighted schemes were within 1% difference to the ideal four-input noise estimator results on average, across all tested duty cycles.

Significance Advanced dimensionality reduction techniques, such as those presented in this work, that merge multi-channel spectral CT data illustrate a potential in improvement the accuracy of iodine contrast material measurement, while filling clinical specifications. This study also indicates the significant role that hybird spectral CT technologies could play in elevating the reliability of quantitative CT.

Competing Interest Statement

PN has received a hardware grant from Philips Healthcare. PN receives research grant funding from Philips Healthcare. AP, KB, and RM are employees of Philips Healthcare. HD and TK are employees of Philips Innovative Technologies. The other authors have no relevant conflicts of interest to disclose.

Funding Statement

We acknowledge support through the National Institutes of Health (R01EB030494).

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

All data produced in the present study are available upon reasonable request to the authors

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted February 20, 2024.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
A computationally efficient method for dimensionality reduction in multi-channel spectral CT
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
A computationally efficient method for dimensionality reduction in multi-channel spectral CT
Olivia F. Sandvold, Roland Proksa, Heiner Daerr, Amy E. Perkins, Kevin M. Brown, Thomas Koehler, Ravindra M. Manjeshwar, Peter B. Noël
medRxiv 2024.02.18.24302905; doi: https://doi.org/10.1101/2024.02.18.24302905
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
A computationally efficient method for dimensionality reduction in multi-channel spectral CT
Olivia F. Sandvold, Roland Proksa, Heiner Daerr, Amy E. Perkins, Kevin M. Brown, Thomas Koehler, Ravindra M. Manjeshwar, Peter B. Noël
medRxiv 2024.02.18.24302905; doi: https://doi.org/10.1101/2024.02.18.24302905

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Radiology and Imaging
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)