Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

High Resolution Multi-delay Arterial Spin Labeling with Transformer based Denoising for Pediatric Perfusion MRI

View ORCID ProfileQinyang Shou, View ORCID ProfileChenyang Zhao, View ORCID ProfileXingfeng Shao, View ORCID ProfileMegan M Herting, View ORCID ProfileDanny JJ Wang
doi: https://doi.org/10.1101/2024.03.04.24303727
Qinyang Shou
1University of Southern California, Los Angeles, California 90033 USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Qinyang Shou
Chenyang Zhao
1University of Southern California, Los Angeles, California 90033 USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Chenyang Zhao
Xingfeng Shao
1University of Southern California, Los Angeles, California 90033 USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Xingfeng Shao
Megan M Herting
1University of Southern California, Los Angeles, California 90033 USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Megan M Herting
Danny JJ Wang
1University of Southern California, Los Angeles, California 90033 USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Danny JJ Wang
  • For correspondence: jwang71{at}gmail.com
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Multi-delay arterial spin labeling (MDASL) can quantitatively measure cerebral blood flow (CBF) and arterial transit time (ATT), which is particularly suitable for pediatric perfusion imaging. Here we present a high resolution (iso-2mm) MDASL protocol and performed test-retest scans on 21 typically developing children aged 8 to 17 years. We further proposed a Transformer-based deep learning (DL) model with k-space weighted image average (KWIA) denoised images as reference for training the model. The performance of the model was evaluated by the SNR of perfusion images, as well as the SNR, bias and repeatability of the fitted CBF and ATT maps. The proposed method was compared to several benchmark methods including KWIA, joint denoising and reconstruction with total generalized variation (TGV) regularization, as well as directly applying a pretrained Transformer model on a larger dataset. The results show that the proposed Transformer model with KWIA reference can effectively denoise multi-delay ASL images, not only improving the SNR for perfusion images of each delay, but also improving the SNR for the fitted CBF and ATT maps. The proposed method also improved test-retest repeatability of whole-brain perfusion measurements. This may facilitate the use of MDASL in neurodevelopmental studies to characterize typical and aberrant brain development.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

This study was funded by National Institute of Health (NIH) grants UF1-NS100614, R01-NS114382, R01-EB032169, R01-EB028297, UF1-NS100588, and U24-NS100591.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

IRB of University of Southern California gave ethical approval for this work.

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Footnotes

  • This work was supported in part by the U.S. National Institute of Health under Grant R01-NS114382, R01-EB032169, and R01-EB028297.

  • (e-mail: qinyangs{at}usc.edu; zhao361{at}usc.edu; xingfens{at}usc.edu; herting{at}usc.edu;).

Data Availability

All data produced in the present study are available upon reasonable request to the authors

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted March 06, 2024.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
High Resolution Multi-delay Arterial Spin Labeling with Transformer based Denoising for Pediatric Perfusion MRI
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
High Resolution Multi-delay Arterial Spin Labeling with Transformer based Denoising for Pediatric Perfusion MRI
Qinyang Shou, Chenyang Zhao, Xingfeng Shao, Megan M Herting, Danny JJ Wang
medRxiv 2024.03.04.24303727; doi: https://doi.org/10.1101/2024.03.04.24303727
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
High Resolution Multi-delay Arterial Spin Labeling with Transformer based Denoising for Pediatric Perfusion MRI
Qinyang Shou, Chenyang Zhao, Xingfeng Shao, Megan M Herting, Danny JJ Wang
medRxiv 2024.03.04.24303727; doi: https://doi.org/10.1101/2024.03.04.24303727

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Radiology and Imaging
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)