Feasibility to virtually generate T2 fat-saturated breast MRI by convolutional neural networks

View ORCID ProfileAndrzej Liebert, View ORCID ProfileDominique Hadler, View ORCID ProfileChris Ehring, View ORCID ProfileHannes Schreiter, View ORCID ProfileLuise Brock, View ORCID ProfileLorenz A. Kapsner, View ORCID ProfileJessica Eberle, View ORCID ProfileRamona Erber, Julius Emons, View ORCID ProfileFrederik B. Laun, View ORCID ProfileMichael Uder, View ORCID ProfileEvelyn Wenkel, View ORCID ProfileSabine Ohlmeyer, View ORCID ProfileSebastian Bickelhaupt
doi: https://doi.org/10.1101/2024.06.25.24309404
Andrzej Liebert
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Andrzej Liebert
  • For correspondence: andrzej.liebert{at}uk-erlangen.de
Dominique Hadler
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Dominique Hadler
Chris Ehring
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Chris Ehring
Hannes Schreiter
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Hannes Schreiter
Luise Brock
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Luise Brock
Lorenz A. Kapsner
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
2Lehrstuhl für Medizinische Informatik, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Lorenz A. Kapsner
Jessica Eberle
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Jessica Eberle
Ramona Erber
3Institute of Pathology, University Regensburg, Regensburg, Germany
4Institute of Pathology, Universitätsklinikum Erlangen, Erlangen, Comprehensive Cancer Center Erlangen-EMN, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Ramona Erber
Julius Emons
5Department of Gynecology and Obstetrics, Erlangen University Hospital, Comprehensive Cancer Center Erlangen-EMN, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Frederik B. Laun
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Frederik B. Laun
Michael Uder
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Michael Uder
Evelyn Wenkel
6Medizinische Fakultät, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany. Radiologie München, München, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Evelyn Wenkel
Sabine Ohlmeyer
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Sabine Ohlmeyer
Sebastian Bickelhaupt
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
7German Cancer Research Center (DKFZ), Heidelberg, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Sebastian Bickelhaupt
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Supplementary material
  • Data/Code
  • Preview PDF
Loading

Abstract

Background Breast magnetic resonance imaging (MRI) protocols often include T2-weighted fat-saturated (T2w-FS) sequences, which are vital for tissue characterization but significantly increase scan time.

Purpose This study aims to evaluate whether a 2D-U-Net neural network can generate virtual T2w-FS images from routine multiparametric breast MRI sequences.

Materials and Methods This IRB approved, retrospective study included n=914 breast MRI examinations performed between January 2017 and June 2020. The dataset was divided into training (n=665), validation (n=74), and test sets (n=175). The U-Net was trained on T1-weighted (T1w), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) sequences to generate virtual T2w-FS images (VirtuT2). Quantitative metrics and a qualitative multi-reader assessment by two radiologists were used to evaluate the VirtuT2 images.

Results VirtuT2 images demonstrated high structural similarity (SSIM=0.87) and peak signal-to-noise ratio (PSNR=24.90) compared to original T2w-FS images. High level of the frequency error norm (HFNE=0.87) indicates strong blurring presence in the VirtuT2 images, which was also confirmed in qualitative reading. Radiologists correctly identified VirtuT2 images with 92.3% and 94.2% accuracy, respectively. No significant difference in diagnostic image quality (DIQ) was noted for one reader (p=0.21), while the other reported significantly lower DIQ for VirtuT2 (p<=0.001). Moderate inter-reader agreement was observed for edema detection on T2w-FS images (ƙ=0.43), decreasing to fair on VirtuT2 images (ƙ=0.36).

Conclusion The 2D-U-Net can technically generate virtual T2w-FS images with high similarity to real T2w-FS images, though blurring remains a limitation. Further investigation of other architectures and using larger datasets are needed to improve clinical applicability.

Summary Statement Virtual T2-weighted fat-saturated images can be generated from routine breast MRI sequences using convolutional neural networks, showing high structural similarity but with notable blurring, necessitating further refinement for clinical use.

Key Results

  1. Images with T2w-FS characteristics can be virtually generated from T1w and DWI images using deep learning

  2. Image blurring occurring in the VirtuT2 image limit clinical use for the current moment

  3. Further investigation of different architectures and with larger datasets are necessary in the future to improve the VirtuT2 performance.

Competing Interest Statement

Authors H.S., A.L., S.B. have pending patent EPO No. 21197259.1 on topic of this manuscript.

Funding Statement

This project is funded by the Bavarian State Ministry of Science and the Arts in the framework of the bidt Graduate Center for Postdocs.

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

The ethics committee of the Friedrich-Alexander Univeristy Erlangen-Nurnberg approved this retrospective study and waived the need for informed consent.

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

Original image data used in this work are not publicly available to preserve individuals privacy under the European General Data Protection Regulation. The institution handling this data is the Institute of Radiology, University Hospital Erlangen.

  • Abbreviations

    CE
    contrast enhanced
    SSIM
    structural similarity index
    PSNR
    peak signal-to-noise-ratio
    HMI
    histogram mutual information
    NRMSE
    normalized root mean square error
    MEDSYMAC
    median symmetrical accuracy
    HFEN
    high frequency error norm
    DWI
    diffusion weighted imaging
  • Copyright 
    The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY 4.0 International license.
    Back to top
    PreviousNext
    Posted June 25, 2024.
    Download PDF

    Supplementary Material

    Data/Code
    Email

    Thank you for your interest in spreading the word about medRxiv.

    NOTE: Your email address is requested solely to identify you as the sender of this article.

    Enter multiple addresses on separate lines or separate them with commas.
    Feasibility to virtually generate T2 fat-saturated breast MRI by convolutional neural networks
    (Your Name) has forwarded a page to you from medRxiv
    (Your Name) thought you would like to see this page from the medRxiv website.
    CAPTCHA
    This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
    Share
    Feasibility to virtually generate T2 fat-saturated breast MRI by convolutional neural networks
    Andrzej Liebert, Dominique Hadler, Chris Ehring, Hannes Schreiter, Luise Brock, Lorenz A. Kapsner, Jessica Eberle, Ramona Erber, Julius Emons, Frederik B. Laun, Michael Uder, Evelyn Wenkel, Sabine Ohlmeyer, Sebastian Bickelhaupt
    medRxiv 2024.06.25.24309404; doi: https://doi.org/10.1101/2024.06.25.24309404
    Twitter logo Facebook logo LinkedIn logo Mendeley logo
    Citation Tools
    Feasibility to virtually generate T2 fat-saturated breast MRI by convolutional neural networks
    Andrzej Liebert, Dominique Hadler, Chris Ehring, Hannes Schreiter, Luise Brock, Lorenz A. Kapsner, Jessica Eberle, Ramona Erber, Julius Emons, Frederik B. Laun, Michael Uder, Evelyn Wenkel, Sabine Ohlmeyer, Sebastian Bickelhaupt
    medRxiv 2024.06.25.24309404; doi: https://doi.org/10.1101/2024.06.25.24309404

    Citation Manager Formats

    • BibTeX
    • Bookends
    • EasyBib
    • EndNote (tagged)
    • EndNote 8 (xml)
    • Medlars
    • Mendeley
    • Papers
    • RefWorks Tagged
    • Ref Manager
    • RIS
    • Zotero
    • Tweet Widget
    • Facebook Like
    • Google Plus One

    Subject Area

    • Radiology and Imaging
    Subject Areas
    All Articles
    • Addiction Medicine (349)
    • Allergy and Immunology (668)
    • Allergy and Immunology (668)
    • Anesthesia (181)
    • Cardiovascular Medicine (2648)
    • Dentistry and Oral Medicine (316)
    • Dermatology (223)
    • Emergency Medicine (399)
    • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
    • Epidemiology (12228)
    • Forensic Medicine (10)
    • Gastroenterology (759)
    • Genetic and Genomic Medicine (4103)
    • Geriatric Medicine (387)
    • Health Economics (680)
    • Health Informatics (2657)
    • Health Policy (1005)
    • Health Systems and Quality Improvement (985)
    • Hematology (363)
    • HIV/AIDS (851)
    • Infectious Diseases (except HIV/AIDS) (13695)
    • Intensive Care and Critical Care Medicine (797)
    • Medical Education (399)
    • Medical Ethics (109)
    • Nephrology (436)
    • Neurology (3882)
    • Nursing (209)
    • Nutrition (577)
    • Obstetrics and Gynecology (739)
    • Occupational and Environmental Health (695)
    • Oncology (2030)
    • Ophthalmology (585)
    • Orthopedics (240)
    • Otolaryngology (306)
    • Pain Medicine (250)
    • Palliative Medicine (75)
    • Pathology (473)
    • Pediatrics (1115)
    • Pharmacology and Therapeutics (466)
    • Primary Care Research (452)
    • Psychiatry and Clinical Psychology (3432)
    • Public and Global Health (6527)
    • Radiology and Imaging (1403)
    • Rehabilitation Medicine and Physical Therapy (814)
    • Respiratory Medicine (871)
    • Rheumatology (409)
    • Sexual and Reproductive Health (410)
    • Sports Medicine (342)
    • Surgery (448)
    • Toxicology (53)
    • Transplantation (185)
    • Urology (165)