Regulating AI Adaptation: An Analysis of AI Medical Device Updates

Kevin Wu, Eric Wu, Kit Rodolfa, Daniel E. Ho, James Zou
doi: https://doi.org/10.1101/2024.06.26.24309506
Kevin Wu
1Stanford University, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: kewu93{at}gmail.com
Eric Wu
1Stanford University, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kit Rodolfa
1Stanford University, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Daniel E. Ho
1Stanford University, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
James Zou
1Stanford University, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

While the pace of development of AI has rapidly progressed in recent years, the implementation of safe and effective regulatory frameworks has lagged behind. In particular, the adaptive nature of AI models presents unique challenges to regulators as updating a model can improve its performance but also introduce safety risks. In the US, the Food and Drug Administration (FDA) has been a forerunner in regulating and approving hundreds of AI medical devices. To better understand how AI is updated and its regulatory considerations, we systematically analyze the frequency and nature of updates in FDA-approved AI medical devices. We find that less than 2% of all devices report having been updated by being re-trained on new data. Meanwhile, nearly a quarter of devices report updates in the form of new functionality and marketing claims. As an illustrative case study, we analyze pneumothorax detection models and find that while model performance can degrade by as much as 0.18 AUC when evaluated on new sites, re-training on site-specific data can mitigate this performance drop, recovering up to 0.23 AUC. However, we also observed significant degradation on the original site after retraining using data from new sites, providing insight from one example that challenges the current one-model-fits-all approach to regulatory approvals. Our analysis provides an in-depth look at the current state of FDA-approved AI device updates and insights for future regulatory policies toward model updating and adaptive AI.

Data and Code Availability The primary data used in this study are publicly available through the FDA website. Our analysis of the data and code used is available in the supplementary material and will be made publicly available on GitHub at https://github.com/kevinwu23/AIUpdating.

Institutional Review Board (IRB) Our research does not require IRB approval.

Competing Interest Statement

The authors have declared no competing interest.

Funding Statement

This study did not receive any funding

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Footnotes

  • kevinywu{at}stanford.edu

  • wue{at}stanford.edu

  • krodolfa{at}law.stanford.edu

  • dho{at}law.stanford.edu

  • jamesz{at}stanford.edu

Data Availability

Data are available on our GitHub repository

https://github.com/kevinwu23/AIUpdating

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted June 28, 2024.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Regulating AI Adaptation: An Analysis of AI Medical Device Updates
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Regulating AI Adaptation: An Analysis of AI Medical Device Updates
Kevin Wu, Eric Wu, Kit Rodolfa, Daniel E. Ho, James Zou
medRxiv 2024.06.26.24309506; doi: https://doi.org/10.1101/2024.06.26.24309506
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Regulating AI Adaptation: An Analysis of AI Medical Device Updates
Kevin Wu, Eric Wu, Kit Rodolfa, Daniel E. Ho, James Zou
medRxiv 2024.06.26.24309506; doi: https://doi.org/10.1101/2024.06.26.24309506

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Health Informatics
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)