Skip to main content
medRxiv
  • Home
  • About
  • Submit
  • ALERTS / RSS
Advanced Search

Quantification of Patent Foramen Ovale Shunt Severity by Transesophageal Echocardiogram and Transcranial Doppler in Routine Clinical Practice

Philip Y. Sun, View ORCID ProfileJonathan M. Tobis, Samuel A. Daneshvar, Rodel C. Alfonso, View ORCID ProfileDavid S. Liebeskind, View ORCID ProfileJeffrey L. Saver
doi: https://doi.org/10.1101/2024.07.12.24310355
Philip Y. Sun
1Department of Neurology, David Geffen School of Medicine (DGSOM), University of California - Los Angeles (UCLA).
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: philipsun1985{at}gmail.com
Jonathan M. Tobis
2Program in Interventional Cardiology, Division of Cardiology, DGSOM, UCLA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Jonathan M. Tobis
Samuel A. Daneshvar
2Program in Interventional Cardiology, Division of Cardiology, DGSOM, UCLA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rodel C. Alfonso
3Quality Management Services, Ronald Reagan UCLA Medical Center
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
David S. Liebeskind
1Department of Neurology, David Geffen School of Medicine (DGSOM), University of California - Los Angeles (UCLA).
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for David S. Liebeskind
Jeffrey L. Saver
1Department of Neurology, David Geffen School of Medicine (DGSOM), University of California - Los Angeles (UCLA).
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Jeffrey L. Saver
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Background The presence of a large physiologic shunt, defined as >20 left atrial microbubbles within 3 cardiac cycles on transesophageal echocardiography (TEE) is a randomized controlled trial- validated indication for patent foramen ovale (PFO) closure in patients with otherwise cryptogenic ischemic stroke. The frequency with which this information is available to treating physicians from clinical TEE reports has not been well delineated.

Methods Among consecutive ischemic stroke patients admitted to an academic medical center undergoing TEE between October 2022 - September 2023, TEE reports were reviewed to determine frequency with which formal clinical-trial definition-adherent characterization of PFO shunt size was provided, the frequency of informal PFO shunt size descriptions, and correlations with transcranial Doppler (TCD) formal shunt grades (Spencer Grades 1-5).

Results Among 77 patients, the median age was 64 (IQR 56-73), and 33 (43%) were female. On TEE, shunt presence was assessed by bubble study in 60 (78%), direct Doppler alone in 5 (7%), and neither in 12 (16%). Among patients with bubble study, a right-to-left shunt (RLS) potentially due to PFO was present 25 (42%). RLS severity was quantified on the clinical report in 16% (4/25) of PFO patients, all with small (<20) shunts. For the remaining 21 (84%), reports informally characterized shunt severity with various descriptive terms, including “small/mild/trace” (13 cases), “moderate/medium” (6), and “large” (1). TCD bubble studies were performed in 76% (19/25) of the TEE RLS PFO patients. Shunt severity correlation between TEE and TCD was 100% (3/3) for the formally quantified TEE shunts, un- assessable in one patient with non-specific shunt size characterization on TEE, and poor (3/15, 20%) for the remaining 15 informally assessed TEE shunts, with 47% (7/15) of shunts categorized as larger on TCD and 33% (5/15) smaller on TCD than TEE.

Conclusions Quantified, evidence-based ratings of PFO shunt severity were present in less than 1 of every 6 TEE reports, and unquantified, informal size estimates correlated poorly with TCD quantification of shunt severity. Patient management would be aided by inclusion of formal PFO shunt size quantification in all clinical stroke patient TEE reports.

Competing Interest Statement

P.Y.Sun: None.J.M.Tobis: n/a. D.S.Liebeskind: Consultant; ; Cerenovus, Genentech, Medtronic, Stryker, Rapid Medical. R.C.Alfonso: None. J.L.Saver: Consultant; ; Medtronic, Abbott, Roche, BrainsGate, BrainQ, Bayer, CSL Behring, Rapid Medical, Novo Nordisk, Individual Stocks/Stock Options; ; QuantalX. There are no unlabeled/unapproved uses of drugs or products.

Funding Statement

None

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

This study was approved by the University of California Los Angeles Institutional Review Board and performed under a waiver of explicit consent for a minimal risk study of existing electronic medical record data.

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

The raw data supporting the conclusions of this article will be made available by the authors upon reasonable requests, without undue reservation.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. It is made available under a CC-BY-NC-ND 4.0 International license.
Back to top
PreviousNext
Posted July 14, 2024.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Quantification of Patent Foramen Ovale Shunt Severity by Transesophageal Echocardiogram and Transcranial Doppler in Routine Clinical Practice
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Quantification of Patent Foramen Ovale Shunt Severity by Transesophageal Echocardiogram and Transcranial Doppler in Routine Clinical Practice
Philip Y. Sun, Jonathan M. Tobis, Samuel A. Daneshvar, Rodel C. Alfonso, David S. Liebeskind, Jeffrey L. Saver
medRxiv 2024.07.12.24310355; doi: https://doi.org/10.1101/2024.07.12.24310355
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Quantification of Patent Foramen Ovale Shunt Severity by Transesophageal Echocardiogram and Transcranial Doppler in Routine Clinical Practice
Philip Y. Sun, Jonathan M. Tobis, Samuel A. Daneshvar, Rodel C. Alfonso, David S. Liebeskind, Jeffrey L. Saver
medRxiv 2024.07.12.24310355; doi: https://doi.org/10.1101/2024.07.12.24310355

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Cardiovascular Medicine
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)