Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm

View ORCID ProfileJessica Y. Im, View ORCID ProfileSandra S. Halliburton, View ORCID ProfileKai Mei, Amy E. Perkins, Eddy Wong, Leonid Roshkovan, View ORCID ProfileOlivia F. Sandvold, View ORCID ProfileLeening P. Liu, View ORCID ProfileGrace J. Gang, View ORCID ProfilePeter B. Noël
doi: https://doi.org/10.1101/2023.12.07.23299625
Jessica Y. Im
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
2Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Jessica Y. Im
  • For correspondence: fanjessica234{at}gmail.com
Sandra S. Halliburton
3Philips Healthcare, Orange Village, OH, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Sandra S. Halliburton
Kai Mei
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Kai Mei
Amy E. Perkins
3Philips Healthcare, Orange Village, OH, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Eddy Wong
3Philips Healthcare, Orange Village, OH, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Leonid Roshkovan
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Olivia F. Sandvold
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
2Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Olivia F. Sandvold
Leening P. Liu
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
2Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Leening P. Liu
Grace J. Gang
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Grace J. Gang
Peter B. Noël
1Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • ORCID record for Peter B. Noël
  • Abstract
  • Full Text
  • Info/History
  • Metrics
  • Data/Code
  • Preview PDF
Loading

Abstract

Objective Deep learning reconstruction (DLR) algorithms exhibit object-dependent resolution and noise performance. Thus, traditional geometric CT phantoms cannot fully capture the clinical imaging performance of DLR. This study uses a patient-derived 3D-printed PixelPrint lung phantom to evaluate a commercial DLR algorithm across a wide range of radiation dose levels.

Approach The lung phantom used in this study is based on a patient chest CT scan containing ground glass opacities and was fabricated using PixelPrint 3D-printing technology. The phantom was placed inside two different sized extension rings to mimic a small and medium sized patient and was scanned on a conventional CT scanner at exposures between 0.5 and 20 mGy. Each scan was reconstructed using filtered back projection (FBP), iterative reconstruction, and DLR at five levels of denoising. Image noise, contrast to noise ratio (CNR), root mean squared error (RMSE), structural similarity index (SSIM), and multi-scale SSIM (MS SSIM) were calculated for each image.

Main Results DLR demonstrated superior performance compared to FBP and iterative reconstruction for all measured metrics in both phantom sizes, with better performance for more aggressive denoising levels. DLR was estimated to reduce dose by 25-83% in the small phantom and by 50-83% in the medium phantom without decreasing image quality for any of the metrics measured in this study. These dose reduction estimates are more conservative compared to the estimates obtained when only considering noise and CNR with a non-anatomical physics phantom.

Significance DLR has the capability of producing diagnostic image quality at up to 83% lower radiation dose which can improve the clinical utility and viability of lower dose CT scans. Furthermore, the PixelPrint phantom used in this study offers an improved testing environment with more realistic tissue structures compared to traditional CT phantoms, allowing for structure-based image quality evaluation beyond noise and contrast-based assessments.

Competing Interest Statement

PN has received a hardware grant from Philips Healthcare. PN receives research grant funding from Philips Healthcare. SH, AP, and EW are employees of Philips Healthcare. The other authors have no relevant conflicts of interest to disclose.

Funding Statement

We acknowledge support through the National Institutes of Health (R01EB030494, R01EB031592, R01HL166236, & R01CA249538).

Author Declarations

I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.

Yes

The details of the IRB/oversight body that provided approval or exemption for the research described are given below:

The Institutional Review Board (IRB) at the University of Pennsylvania approved this retrospective study.

I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.

Yes

I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).

Yes

I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.

Yes

Data Availability

All data produced in the present study are available upon reasonable request to the authors.

Copyright 
The copyright holder for this preprint is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. All rights reserved. No reuse allowed without permission.
Back to top
PreviousNext
Posted December 09, 2023.
Download PDF
Data/Code
Email

Thank you for your interest in spreading the word about medRxiv.

NOTE: Your email address is requested solely to identify you as the sender of this article.

Enter multiple addresses on separate lines or separate them with commas.
Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm
(Your Name) has forwarded a page to you from medRxiv
(Your Name) thought you would like to see this page from the medRxiv website.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Share
Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm
Jessica Y. Im, Sandra S. Halliburton, Kai Mei, Amy E. Perkins, Eddy Wong, Leonid Roshkovan, Olivia F. Sandvold, Leening P. Liu, Grace J. Gang, Peter B. Noël
medRxiv 2023.12.07.23299625; doi: https://doi.org/10.1101/2023.12.07.23299625
Twitter logo Facebook logo LinkedIn logo Mendeley logo
Citation Tools
Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm
Jessica Y. Im, Sandra S. Halliburton, Kai Mei, Amy E. Perkins, Eddy Wong, Leonid Roshkovan, Olivia F. Sandvold, Leening P. Liu, Grace J. Gang, Peter B. Noël
medRxiv 2023.12.07.23299625; doi: https://doi.org/10.1101/2023.12.07.23299625

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Subject Area

  • Radiology and Imaging
Subject Areas
All Articles
  • Addiction Medicine (349)
  • Allergy and Immunology (668)
  • Allergy and Immunology (668)
  • Anesthesia (181)
  • Cardiovascular Medicine (2648)
  • Dentistry and Oral Medicine (316)
  • Dermatology (223)
  • Emergency Medicine (399)
  • Endocrinology (including Diabetes Mellitus and Metabolic Disease) (942)
  • Epidemiology (12228)
  • Forensic Medicine (10)
  • Gastroenterology (759)
  • Genetic and Genomic Medicine (4103)
  • Geriatric Medicine (387)
  • Health Economics (680)
  • Health Informatics (2657)
  • Health Policy (1005)
  • Health Systems and Quality Improvement (985)
  • Hematology (363)
  • HIV/AIDS (851)
  • Infectious Diseases (except HIV/AIDS) (13695)
  • Intensive Care and Critical Care Medicine (797)
  • Medical Education (399)
  • Medical Ethics (109)
  • Nephrology (436)
  • Neurology (3882)
  • Nursing (209)
  • Nutrition (577)
  • Obstetrics and Gynecology (739)
  • Occupational and Environmental Health (695)
  • Oncology (2030)
  • Ophthalmology (585)
  • Orthopedics (240)
  • Otolaryngology (306)
  • Pain Medicine (250)
  • Palliative Medicine (75)
  • Pathology (473)
  • Pediatrics (1115)
  • Pharmacology and Therapeutics (466)
  • Primary Care Research (452)
  • Psychiatry and Clinical Psychology (3432)
  • Public and Global Health (6527)
  • Radiology and Imaging (1403)
  • Rehabilitation Medicine and Physical Therapy (814)
  • Respiratory Medicine (871)
  • Rheumatology (409)
  • Sexual and Reproductive Health (410)
  • Sports Medicine (342)
  • Surgery (448)
  • Toxicology (53)
  • Transplantation (185)
  • Urology (165)